Appendix
83
6.0
Appendix
6.1
Error Codes
For the single-line Uni-3L1 in some cases pressing the Up or Down arrow keys will toggle between the error
number and the description.
Error No.
Error
Description
105
Initialization Failed
Perform memory initialization, see Section 4.6 on page 66
106
Battery is Fault
Verify battery switch is on or replace battery
108
Clock Setting is Not Completed Yet
Set up clock, see Section 4.2 on page 65
109
Printer 1 Initialization Was Not Done Yet
Initialize printer one, see Section 4.7 on page 67
110
Machine Setting Is Not Completed
Select machine type, see Section 4.11 on page 70
111
The Display Confirmation Is Not Completed
Perform key check, see Section 4.4 on page 65
112
The Confirmation Of The Key Is Not Completed
Perform key check, see Section 4.4 on page 65
114
The Data Composition Is Different
Initialize the memory, see Section 4.6 on page 66
116
The Country Has Not Been Selected
Select country, see Section 3.20 on page 57
202
PLU Master Is Not Programmed
Check PLU number, program if necessary,
see Section 5.1 on page 72
203
POP Master Is Not Programmed
Check POP number, program if necessary,
see Section 5.13 on page 81
212-216
Free Master Isn’t Registered
Check Free Message, register if necessary,
see Section 5.16 on page 82
219
Store Master Is Not Programmed
Check store number, program if necessary,
see Section 5.6 on page 78
221
Tare Limit Over (g)
Re-program tare weight
222
Tare Weight is 0 g
Set tare weight
223
Label Setting Master Is Not Programmed
Check label number, program if necessary
266-000
File Input Error
There is a file that failed during input, check USB
266-001
File Input Error
Failed in reconstruction of SRAM data
267-000
File Output Error
There is a file that failed during output, check USB
267-001
File Output Error
Failed in SRAM data backup
268-000
File Delete Error
There is a master file that failed in deleting
268-001
File Delete Error
Failed in SRAM delete
268-002
File Delete Error
Failed in Data delete
268-003
File Delete Error
There is data that failed in deleting
271
Initialize Error
There is master data that failed in initialization
275
Extra Message 1 not found
The extra message 1 linked to the PLU does not exist. This error
message can be disabled at step B18-02-03.
276
Extra Message 2 not found
The extra message 2 linked to the PLU does not exist. This error
message can be disabled at step B18-02-04.
277
Extra Message 3 not found
The extra message 3 linked to the PLU does not exist. This error
message can be disabled at step B18-02-05.
281
Tare Limit Over (kg)
Re-program tare weight
282
Tare Weight is 0 kg
Set tare weight
283
Tare Limit Over (lb)
Re-program tare weight
284
Tare Weight is 0 lb
Set tare weight
312-000
Label Is Remaining
Remove label or check peel sensor levels,
see Section 4.7 on page 67
313
Printer Thermal Head Is Up
Put thermal head down
316
Markdown Price Is More Than Original Price
Check price, markdown should be less than original price
321
Price Is Not Programmed
Enter price, program if necessary