Uni-3 Technical Manual
4.8
C08-Calibration
Set the scale’s capacity and range and calibrate the weight readings.
4.8.1
Calibrate the Scale
1. Remove any objects from the platter and press the
Zero
key. Display reads: Span= 20000, Weight= 0.000.
2. Place full capacity weight on the scale, example 30 lb.
3. Press
Tare
. Display reads: Span= 80000, Weight= 30.00.
C07-04
Label Feed
C07-04-01 Sensor Type
Specifies if the Label Gap sensor is active.
0: NONE
1: LABEL
C07-04-03 Label Sensor Level & Sensitivity Enter a value to adjust the label sensor.
• Backing Paper Only: Approximately 150
• Backing Paper and Label: Approximately 50
0-255
C07-04-04 Label Gap Detect
Adjusts the threshold value of the label gap
sensor. Any sensor readings below the set value
are ignored. This is useful when the label has
dark pre-printed areas that affect the sensor
output.
0-255
C07-04-05 Pre-Print Length
Adjusts the length of the preprint section. Specify
the length in 0.1 millimeters. Default is 7.5 mm.
--
C07-04-06 Label Sensor Distance
Specifies the distance between the label gap
sensor and the print elements on the thermal
head. Specify distance in 0.1 millimeters. Default
is 71.0 mm.
--
CO7-04-07 Back Feed
Turns the backward feeding on or off.
1: NO
2: YES
C07-04-08 Peel Sensor
Specifies if the peel sensor is active.
0: USE
1: NO USE
Display
Description
Choices
C08-01 Capacity
Specifies the scale’s maximum capacity and units.
Changes to the capacity selection will not be saved until
calibration is performed.
Do not select 60 lb (or 30 kg) unless the scale is
equipped with a high capacity load cell.
0: 15 kg
1: 30 kg
2: 30 lb
3: 60 lb
9: 30 kg (1/6000)
C08-02 Range
Specifies the accuracy of the scale.
Example
:
Single: 0-30 x 0.01 lb Multi: 0-15 x 0.005 lb, 15-30 x 0.01 lb
Changes to the range selection will not be saved until a
calibration is performed.
0: SINGLE
1: MULTI
C08-03 Area Setting
Gravity setting. Used when the scale is calibrated in one location and used at
another. This step is password protected.
--
C08-04 Advanced Setting
Enables steps C08-05 to C08-08. Used for factory verification.
1: OFF
2: ON
C08-09 Initialize
Initializes calibration parameter. All settings are reset to default values after
initialization. To store settings again, perform the zero point adjustment and
the span adjustment. Press the span button to store the settings.
Use this function only when calibration is not operating
normally.
--
C08-10 Span Calibration
See Section 4.8.1 below.
--
Table 4-6. C08 Calibration
Parameter
Display
Description
Choices
Table 4-5. C07 Printer Parameters (Continued)
CO8 CALIBRATION