8/54
IWQ Series Service Manual
2.2 Procedures of Installation and Placement
1. Unpack and confirm the following attached parts.
6mm flat washers
4 pieces
Bracket
1 piece
Hexagon-headed bolt (M5x10mm) 4 pieces
Bracket
Flat washers
(6mm)
Hexagon-
headed bolts
(M5x10)
Flat washers
(6mm)
2. Mount the display pole.
Although the display and the pole are assembled by the fastening knob, the pole and the bracket
base are not.
Caution
The cell cable may rupture if pulled forcefully. If the cable sheath is damaged, the
cable material may corrode and result in malfunctioning.
(1) Push the excess length of cable into
the support column.
Push the excess cable
Bracket base
Projection A
Display
pole
into the pole.
(2) Put the display pole vertically along
the bracket base side in the way of
inserting the cell cable outlet into the
projection A (above figure).
Bracket base
Display
pole
(3)
Fasten the bracket temporarily with
the flat washers (6mm) and
hexagon-headed bolts (M5x10mm) at
4 points. The bracket is asymmetric
about the mid-horizontal line. The
figure in the right shows the direction
of the bracket when it is fastened.
Fit position
Bracket
Rounded corner
with greater
radius is on top.