14/54
IWQ Series Service Manual
3.2.2 Start-up of Setup Mode, setup, and end of setup
Operation
Display
1. How to start
On the scall OFF state, press the ON/OFF key , and
then (immediately while the buzzer is sounding) press the
CLR key for a while.
Displaying the set item
Set data display Input number display
2. Selecting items F1 to F16
Select one of the three methods;
(1) Proceed in the right direction.
TARE or CALL
Changing successively in the “F1”
→
“F2”
→
“F3”…order.
(2) Proceed in the reverse direction.
TARE SET
Changing successively in the “F1”
→
“F16”
→
“F15”…order.
(3) Input item number and call up.
Input item number(s)
, then
press
CALL.
Displaying the set item
Set data display
Input number display
3. Setting data
Input data and set using the
PCS key.
4. End of setup
Press the
ZERO key.
Normal display