ICV 4030 - CNC-Compact-Machine with CAN Controller
Page - 9
Operating devices to control the machine
number
designation
description
1
Emergency Stop button
Turns off the power supply for the motor power amplifier and the working spindle.
2
Power ON button
Turns on the power supply for the power amplifiers.
3
Fault indicator
The fault indicator indicates an error within the safety circuit.
4
Start button
Starts the processing of the current NC-program or continues an interrupted processing.
5
Stop button
Interrupts the processing of the current NC-program. The repeated pressing of the Stop button will abort
the processing (not for all control configurations valid).
6
Cover button
This button is used to open the hood (if existing). The hood may only be opened when the Cover button
is highlighted (axes must be in HOME position or operating mode switch is set to “Test”).
Note:
To open the hood with the COVER button press the hood shortly down therewith the tongue of the
Schmersal-switch is released. After that push the hood upstairs.
7
ACK (Acknowledge) button
Press this button in order to move the axes when the machine is in setup-mode and the hood is open.
8
operating mode switch
Use this key-operated switch to switch between automatic and setup-mode. In automatic mode the hood
(resp. door) can only be opened when all axes are in their HOME position. In setup-mode the hood can
be opened and pushing the ACK button, axes can be moved.
Operating devices for the control-PC
number
designation
description
9
Power button
Turns on the integrated control-PC.
10
Power-LED
Operation indicator of the control-PC.
11
HDD-LED
Indicator for access to the hard disk.
12
USB slots
USB 2.0 slots for USB devices (USB Stick, WIBU etc.)