Commissioning
6.1
Preliminary notes
This figure present an overview of the electronic components in the Penguin.
À
À
À
À
À
Emergency-Stop
(at the operating console)
Á
Á
Á
Á
Á
Monitor
Â
Â
Â
Â
Â
Keyboard
Ã
Ã
Ã
Ã
Ã
Control computer
Ä
Ä
Ä
Ä
Ä
Power unit
Å
Å
Å
Å
Å
Blank sheet metal
Æ
Æ
Æ
Æ
Æ
Mouse interface
Ç
Ç
Ç
Ç
Ç
Main switch (on the rear side)
È
È
È
È
È
SK module (internal)
Coordinate system
The coordinate system of the
machine is defined as shown
in the figure. Nevertheless, you
can select the P0 workpiece
zero point unrestrictedly via
software (offset).
Stickers on the machine identify the axes.
Please, read the manual of the iseldrv.exe driver if you must modify the configuration of
the coordinates. Contact our technical service in case of questions.
Reference point and home position
Ex works, the reference point of the machine (machine
zero point) and the home position are pre-set to the
corner on the upper left at the back (seen from the front).
This location of the home position is signaled to the
controller using an electromagnetic switch contact. As a
pulse generator, the magnet is fixed to the enclosure.
Without havng a physical contact, the reading contact on
the Z-axis recognizes the home position if it recognizes
the magnetic pulse.