![iseg GPS 300W Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/iseg/gps-300w/gps-300w_technical-documentation-manual_2092520014.webp)
1.5.2 GPS 350W - COMPACT
TECHNICAL DATA
GPS 350W – COMPACT
Output power P
nom
350 W
Polarity
Fixed, positive or negative
Efficiency
> 80% (V
in
= 230 V, P
nom
)
Ripple
(voltage control)
Standard
∆V
out
< 0.25% • V
nom
CLD
∆V
out
< 2.5% • V
nom
Stability
(1
∆V
out
< 0.02% • V
nom
Voltage regulation
Standard
∆V
out
< 0.02% • V
nom
, (∆V
in
, 0 ≤ I
out
≤ I
nom
, 5 V ≤ V
out
≤ V
nom
)
CLD
∆V
out
< 0.1% • V
nom
, (∆V
in
, 0 ≤ I
out
≤ I
nom
, 5 V ≤ V
out
≤ V
nom
)
Current regulation
∆I
out
< 0.2% • I
nom
(∆V
in
, 0 V ≤ V
out
≤ V
nom
,
5 V ≤ V
out
≤ V
nom
Accuracy
(2
Voltage:
< 1 % • V
OUT
Current:
< 1 % • I
OUT
Temperature coefficient
< 200 ppm
Control
AIO
Analog signals:
Level
0 V – 5 V
Digital signals:
Low level
0 V – 1 V
High level
3,5 V – 5 V or open
Supply
V
in
= 85 – 264 VAC (PFC),
I
in
< 5 A (Vin = 85 V, P
nom
), Mains frequency 47 Hz < f < 63 Hz
internally fused with a fuse 2 x 6.3 A with a slow characteristic, inrush current peak
internally limited to max. 25 A
Supply fuse
6.3 A, with slow characteristic
Cooling
Forced cooling, 2-level with integrated fan (≤ 70 m³/h)
Controls
Mains voltage, auxiliary voltage, overvoltage, temperature, ARC
Operating parameters
Temperature:
-20 °C ... 50 °C
Humidity:
20 % ... 90 %, non-condensing
Storage parameters
Temperature:
-25 °C ... 80 °C
Humidity:
20 % ... 90 %, non-condensing
Electromagnetic
Compatibility
Emission
EN 55011 Limit value curve B
Immunity
EN 61000 4-2, EN 61000 4-3, EN 61000 4-4, EN 61000 4-8
Safety standard
EN 61010-1 (VDE 0411)
Arcing (ARC)
See: 2.3 ARC Management
Voltage ramp
Standard
0.25 • V
nom
kV/s
CLD
10 • V
nom
kV/s
Electrically isolated return of the high
voltage
Return conductor and protective conductor are permanently connected
Notes:
1)
for 8 h under constant conditions, after ½ h warmup
2)
for one year
Table 5: Technical data for 350W Series
GPS High Voltage Power Supply Series | Last change: 10.01.2020 |
www.iseg-hv.com
14/40