1.5 Technical data
1.5.1 GPS 300W
TECHNICAL DATA
GPS 300W
Output power P
nom
300 W
Polarity
fixed, positive or negative
Efficiency
> 80% (V
in
= 230 V, P
nom
)
Ripple
(voltage control)
Standard
∆V
out
< 0.01% • V
nom
(> 10 Hz), V
out
≤ 8 kV
∆V
out
< 0.05% • V
nom
(> 10 Hz), V
out
> 8 kV
CLD
∆V
out
< 1.5% • V
nom
(> 10 Hz)
Stability
(1
∆V
out
< 0.01% • V
nom
Voltage regulation
∆V
out
< 0.01% • V
nom
(∆V
in
, 0 ≤ I
out
≤ I
nom
, 5 V ≤ V
out
≤ V
nom
)
Current regulation
∆I
out
< 0.2% • I
nom
(∆V
in
, 5 V ≤ V
out
≤ V
nom
)
Accuracy
(2
Voltage:
< 1 % • V
OUT
Current:
< 1 % • I
OUT
Temperature coefficient
< 200 ppm
Control
AIO
Analog signals:
Level
0 V – 5 V
Digital signals:
Low level
0 V – 1 V
High level
3.5 V – 5 V or open
Supply
V
in
= 85 – 264 VAC (PFC),
I
in
< 1.7 A (V
in
= 230 V, P
nom
),
I
in
< 3.5 A (V
in
= 115 V, P
nom
), Mains frequency 47 Hz < f < 63 Hz
internally fused with a fuse 2
x
6.3 A with a slow characteristic, inrush current peak
internally limited to max. 25 A
Supply fuse
6.3 A, with slow characteristic
Cooling
Forced cooling with integrated fan (≤ 10 m³/h)
Controls
Mains voltage, auxiliary voltage, overvoltage, temperature, ARC
Operating parameters
Temperature:
-20 °C ... 35 °C
Humidity:
20 % ... 90%, non-condensing
Storage parameters
Temperature:
-25 °C ... 80 °C
Humidity:
20 % ... 90%, non-condensing
Electromagnetic
Compatibility
Emission
EN 55011 Limit value curve B
Immunity
EN 61000 4-2, EN 61000 4-3, EN 61000 4-4, EN 61000 4-8
Safety standard
EN 61010-1 (VDE 0411)
Arcing (ARC)
See: 2.3 ARC Management
Voltage ramp
Standard
0.25 • V
nom
kV/s
CLD
10 • V
nom
kV/s
Electrically isolated return of the high
voltage
Potential difference between return conductor and protective conductor
up to ± 400 V
Notes:
1)
for 8 h under constant conditions, after ½ h warmup
2)
for one year
Table 3: Technical data for 300W Series
GPS High Voltage Power Supply Series | Last change: 10.01.2020 |