SPECIFICATIONS
EHS CG
EHS CFG
EHS FG
Operating temperature
0 ... 40 °C
Storage temperature
-20 … 60 °C
Humidity
20
–
80 %, not condensing
Notes:
1)
The resolution of measurable values depends on the settings of the sampling rate and the digital filter!
2)
Factory Settings
Table 1: Technical data: Specifications EHS Standard
CONFIGURATIONS EHS STANDARD SERIES
Type
V
nom
I
nom
Ch
Max. I
in
(A)
at 24V
Ripple (mV
p-p
)
>1kHz|10Hz-1kHz
HV connector
Standard/
opt.
Item Code
Options
Common Ground
EHS F1 05x
500 V
8 mA
16
4
3
10
R51.43
EH161005x805oooccrk
SLA, SLP, ID, IU
EHS 201 05x
500 V
8 mA
32
8
3
10
R51.45
EH321005x805oooccrk
SLA, SLP, ID, IU
EHS F1 10x
1 kV
4 mA
16
4
2
15
R51.43
EH161010x405oooccrk
SLA, SLP, ID, IU
EHS 201 10x
1 kV
4 mA
32
8
2
15
R51.45
EH321010x405oooccrk
SLA, SLP, ID, IU
EHS F1 20x
2 kV
2 mA
16
4
2
20
R51.43
EH161020x205oooccrk
SLA, SLP, ID, IU
EHS 201 20x
2 kV
2 mA
32
8
2
20
R51.45
EH321020x205oooccrk
SLA, SLP, ID, IU
EHS F1 30x
3 kV
1.3 mA
16
4
2
20
R51.43
EH161030x135oooccrk
SLA, SLP, ID, IU
EHS 201 30x
3 kV
1.3 mA
32
8
2
20
R51.45
EH321030x135oooccrk
SLA, SLP, ID, IU
EHS F1 40x
4 kV
1 mA
16
4
3
20
R51.43
EH161040x105oooccrk
SLA, SLP, ID, IU
EHS 201 40x
4 kV
1 mA
32
8
3
20
R51.45
EH321040x105oooccrk
SLA, SLP, ID, IU
Notes:
replacement characters: o – options, c – connector, r – revision, k – customization, x – polarity (negative/positive/mix)
Table 2: Technical data: Configurations of Standard
EHS High Voltage Power Supply series | Last changed on: 2022-03-14 |