iDS6
Series User’s Manual
iS5 Communications Inc.
33
The following table describes the System Event Configuration interface page.
Label
Description
Hardware Reset
(Cold Start)
This refers to starting the system from power off (contrast this with
warm start). When performing a cold start, the Device Server will
automatically issue an Auto warning message by sending E-mail, log
information or an SNMP trap after booting.
Software Reset
(Warm Start)
This refers to restarting the system without turning the power off.
When performing a warm start, the Device Server will automatically
send an E-mail, log information or SNMP trap after reboot.
Login Failed
When an unauthorized access from the Console or Web interface is
detected, a notification will be sent via the selected method.
IP Address
Changed
When the IP address of the Device Server is changed, a notification
will be sent via the selected method.
Password
Changed
When the password of the Device Server is changed, a notification
will be sent via the selected method.
Access IP
Blocked
When a host with a blocked IP address tries to access the device, a
notification will be sent via the selected method.
Redundant
Power Change
When there is a change to the status of power, a notification will be
sent via the selected method.
Redundant
Ethernet
Change
When there is a change to the status of an Ethernet port, a
notification will be sent via the selected method.
DCD changed
When the DCD (Data Carrier Detect) signal changes, indicating that
the modem connection status has been changed, a notification will
be sent via the selected method.
DSR changed
When the DSR (Data Set Ready) signal changes, indicating that the
data communication equipment is powered off, a notification will be
sent via the selected method.
RI changed
When the RI (Ring Indicator) signal changes, indicating an incoming
call, a notification will be sent via the selected method.
CTS changed
When the CTS (Clear To Send) signal changes, indicating that the
transmission between computer and DCE can proceed, a notification
will be sent via the selected method.
Port connected
In the TCP Server Mode, when the device accepts an incoming TCP
connection, this event will be triggered. In TCP Client Mode, when
the device has connected to the remote host, this event will be
triggered. In Virtual COM Mode, when the Virtual COM is ready to
use, this event will be triggered. When the Port connected is
triggered the Device Server will automatically issue an Auto warning
message by sending E-mail, log information or an SNMP trap.
Port
disconnected
In TCP Server/Client Mode, when the device loses the TCP link, this
event will be triggered. In Virtual COM Mode, when the Virtual COM
is not available, this event will be triggered. When the Port
disconnected is triggered the Device Server will automatically issue
an Auto warning message by sending E-mail, log information or an
SNMP trap.
Power 1 Fault
When a Power 1 Fault occurs, a notification will be sent and the Fault
LED will be on.
Power 2 Fault
When a Power 2 Fault occurs, a notification will be sent and Fault