iDS6
Series User’s Manual
iS5 Communications Inc.
14
This cover must be re-attached after wiring to ensure personnel safety
.
The iDS6 series supports dual redundant power supplies (PWR1 and PWR2). There are 3 options:
1.
LV: Dual Input 10-48VDC
2.
MV: Dual Input 36-75VDC
3.
HV: Single Input 88-300VDC or 85-264VAC with a Single 10-48VDC backup.
There are also connections for the Failsafe Relay. Connections to the Terminal block are listed in the
table below.
Terminal Block
Terminal
Number
Description
Connection
1
PWR1 (L) – Live
Connect to the (Live) of DC power supply 1 or (Live)
terminal of an AC power source.
2
PWR1 (G) – Ground
DC Power supply 1 ground connection or AC power
round connection.
3
PWR1 (N) – Neutral
Connect to the Neutral of the DC power supply 1 or
(Neutral) terminal of an AC power source.
4
G – Chassis Ground
Connected to the ground bus for DC inputs or
Safety Ground terminal for AC Units. Chassis
Ground connects to both power supply surge
grounds via a removable jumper.
5
PWR2 (L) – Live
Connect to the (Live) terminal of Power supply 2 or
backup DC power source for HV.
6
PWR2 (G) – Ground
Power supply 2 or backup DC power source ground
connection.
7
PWR2 (N) – Neutral
Connect to the (Neutral) terminal of Power supply
2 the second or backup DC power source for HV.
8
RLY NO
Failsafe Relay, (Normally Open) contact.
9
RLY CM
Failsafe Relay (Common) contact.
10
No Connection