background image

 

 

 

 

27 

To switch off the modem, disable power voltage applied to it. Data transmission over GPRS will be terminat-

ed. 

4.2. Device Operating Procedure 

When enabled,  the modem verifies power supply voltage. If it  is less than the minimal allowed voltage, the 

log will prompt an error message ("POWER ERROR"), and the modem will wait for power voltage sufficient to 

operate. 

After  supplying  voltage  to  the  modem  sufficient  for  operation,  the  SIM  card  is  verified.  If  the  SIM  card  re-

quests a  PIN code,  the modem is loaded using the PIN code specified  in  the settings. When the  PIN code  is 

incorrect, the modem deletes it from the memory to prevent SIM card locking. If the PIN code is not specified in 

the modem settings, but the SIM card requires it, the modem does not operate with this SIM card until the tray 

is restarted. 

After  the  SIM  card's  successful  loading,  the  modem  registers  with  the  network  and  clears  the  memory  of 

SMS messages. The modem establishes GPRS connection and connects to the server (in the 

Client

 mode) / 

opens the port for incoming client connections (in the 

Server 

mode).  

When operating with the standard server (not iRZ Collector), the modem re-establishes connection with it if 

there is no data transmission  within the time interval  (set by the 

Connection Check Interval

 setting). Default 

time interval 

– 10 minutes. Changing the interval as well as learning the current value is only possible via AT 

commands. 

When operating  with the iRZ Collector specialized server,  the modem sends a keepalive packet to the iRZ 

Collector  server  to  verify  connection  if  data  transmission  is  not  available  for  over  a  minute.  If  there  is  no  re-

sponse to the keepalive packets, the server clears the connection. 

When the modem operates in the 

Server

 mode, test connection to the public servers is performed to verify 

connection. For more details on the basic settings, refer to the 

"TCP/IP Connection Control"

 section. 

If going online and connecting to the modem is impossible, the modem repeatedly retries connection at the 

set time intervals (

Connection Retry Interval 

setting). Default value for this parameter is 30 minutes. Chang-

ing the interval as well as learning the current value is only possible via AT commands. 

The modem provides continuous monitoring of pins and checks for incoming

1

 SMS messages. The modem 

checks for SIM cards and switches to the service mode if both trays are not available. 

                                                      

1

 SMS messages received by the modem. Such message may contain the command to connect to the server, enable or 

disable the offline mode or to control the modem pins. For more details on the modem SMS commands, refer to sections 

"Connecting to the Server via SMS Commands"

"Offline Mode"

 

и 

"GPIO Pins Control via SMS Commands"

Содержание ATM2-232

Страница 1: ...Operation Manual GSM modem iRZ ATM2 232...

Страница 2: ...Functional Circuit 12 2 9 Device View 14 2 10 Interfaces 15 2 10 1 Mini USB Connector 15 2 10 2 DB9 Connector RS232 15 2 10 3 Power Connector 17 2 10 4 Terminal Connector 2GPIO 1GPO 17 2 11 The Modem...

Страница 3: ...4 17 3 GPIO Pins Control via SMS Commands 45 4 18 Operating with Incoming SMS Messages 46 4 19 Modem Operation in the Server Mode 46 4 19 1 Authentication of Connecting Clients 47 4 19 2 Monitoring an...

Страница 4: ...to the tray 23 Fig 3 3 The ATM modem drawing dimensions 24 Fig 3 4 Device mounting mounting the modem on a DIN rail on the lateral side 24 Fig 3 5 Device mounting mounting the modem on a DIN rail on t...

Страница 5: ...ng up the modem via AT commands the AT Commands to Set Up the iRZ ATM2 232 Modem document the benefits of the iRZ Collector special purpose server the iRZ Collector Solution Overview docu ment the use...

Страница 6: ...ng connec tions and processes them The system of data collection and device control hereinafter referred to as system a set of tools for automated data collection from external devices located on site...

Страница 7: ...ting system supporting the application External devices polling software is used in the dispatching center to poll external devices and is provid ed by their manufacturer Generally it operates in the...

Страница 8: ...g software is also connected to the server and re quests the data received by the server from the modem External device the device mounted on a site and connected to the modem via the RS232 communica...

Страница 9: ...t communication between a third party external devices polling software and an external device connected to the modem via RS232 interface The modem tracks the GPRS connection sta tus and in case of co...

Страница 10: ...voltages and temperatures During its operation the modem displays messages in the log via USB interface in a real time To view and analyse the log on a computer use any terminal program 2 2 Using the...

Страница 11: ...following physical specifications housing dimensions without connectors max 66 83 25 mm L W D product dimensions with connectors max 74 83 25 mm L W D weight maximum 120 g operating temperature 40 C t...

Страница 12: ...o 30 Current measurement error mA 0 2 Voltage measurement parameters Voltage measuring range V 0 to 40 Voltage measurement error V 0 2 GPIO 1 and 2 in the output mode Output type open collector to gro...

Страница 13: ...roller MC Mini USB RTC module battery 9 pin RS232 DB 9 4 pin terminal connector GPIO 4 pin terminal connector GPIO SIM1 and SIM2 holders SIM1 SIM2 an operating SIM selection module SIM selection LEDs...

Страница 14: ...The numbers in Fig 2 2 and Fig 2 3 illustrate 1 mini USB connector 2 SIM 1 tray SIM 1 3 SIM 1 tray eject button SIM 1 4 SIM 2 tray SIM 2 5 SIM 2 tray eject button SIM 2 6 SIM 1 LED indication SIM 1 7...

Страница 15: ...determines the modem as a virtual COM port The modem is powered via Mini USB interface only for operation in the service mode Fig 2 4 Mini USB Connector Note 1 USB is used in the device mode therefore...

Страница 16: ...damage to the COM port wait at least 5 seconds to plug and unplug connected devices after turning off the power The DCD DSR CTS RING pins can be set to a high or low state in the encapsulation mode se...

Страница 17: ...cify the Modbus ASCII protocol in the modem settings only if it is recommended to use this protocol by the manufacturer of the external device 2 10 3 Power Connector Microfit 4 connector is used to co...

Страница 18: ...t the modem operation the indication is performed via the LED placed above the tray with an active SIM card a SIM card operating at a given moment is called active the second one inactive LED signal i...

Страница 19: ...n GSM network Depending on the CSQ signal strength the LED of each SIM card blinks certain times signal strength is below 9 1 time signal strength is from 9 to 15 2 times signal strength is from 16 to...

Страница 20: ...ver IP address to which the client modem is to be connected and transmit data from an external device It is required to specify a public static IP address of the data collection server or network gate...

Страница 21: ...configuring the modem by AT commands the password should be entered in the terminal program to switch to the modem service mode otherwise you may fail to configure it SMS command password 4 character...

Страница 22: ...m does not provide support for SIM cards of other formats To install the SIM card in the modem follow the steps below 1 Press the button near the SIM card tray using a thin object see 1 in Fig 3 1 2 R...

Страница 23: ...N rail see Fig 3 4 To mount the modem on a DIN rail on the front side use two WAGO mounting brackets see Fig 3 5 Fas ten the mounting brackets with four Din7982 ST2 2x9 self tapping screws at the rear...

Страница 24: ...24 Fig 3 3 The ATM modem drawing dimensions Fig 3 4 Device mounting mounting the modem on a DIN rail on the lateral side...

Страница 25: ...25 Fig 3 5 Device mounting mounting the modem on a DIN rail on the lateral side Fig 3 6 Device mounting mounting the modem on the wall...

Страница 26: ...fy advanced options in the tab Settings Advanced c Save settings specified in the application to the modem using the Write button with an arrow pointing down 3 If you need to use the specified paramet...

Страница 27: ...nnection Check Interval setting Default time interval 10 minutes Changing the interval as well as learning the current value is only possible via AT commands When operating with the iRZ Collector spec...

Страница 28: ...in the log To enter the service mode it is required to enter the corresponding password default value 5492 Before entering the password in the terminal application only the query for the version and m...

Страница 29: ...letters case sensitive Default password 5492 There must be a space after the password in the message Switch to the offline mode by a code word When detecting a set of characters in data stream with t...

Страница 30: ...ven in the document The AT commands for the iRZ ATM2 232 Modem Configuration GPRS access on exact time When this option is enabled the modem will establish GPRS connection at a specified time once a d...

Страница 31: ...in the settings If the modem operates with the iRZ Collector server the modem is connected to the server and sends the of fline mode schedule in the start log when supplying power and exiting the serv...

Страница 32: ...ATM Control Configuration Utility the Device tab The first two digits in the version number stand for the firmware type used by the mo dem 01 factory firmware 02 updatable firmware The next two digits...

Страница 33: ...iguration of the modem The ATM configuration file can be created and saved via the ATM Control utility Note The modem does not handle incoming calls SMS commands and pins signals in the firmware up da...

Страница 34: ...der the access to the server is available when it is not provided for the first address Taking this into account the following combinations with maximum available use of backup one server with two IP...

Страница 35: ...diagram of operation with the server without backup Internet connection see Fig 4 2 the diagram of operation with two servers see Fig 4 3 and the diagram of operation with two IP address es on one se...

Страница 36: ...so serves as a client Two clients cannot intercommunicate directly the server is required This is the iRZ Collector server has been developed It serves as a layer between the modem client and the soft...

Страница 37: ...arting ID text is set in the modem settings via ATM Control application and can consist of any printable and non printable characters as well as insertions of the following info IMEI CSQ SCID oper ati...

Страница 38: ...the modem Putting white space after the password is im perative Format 4 characters Latin characters and digits case sensitive Default value 5492 can be changed in the service mode ATIP208 245 23 12 1...

Страница 39: ...Detecting active signal at GPIO2 pin tab Settings Advanced GPIO GPIO2 Fig 4 5 Outgoing SMS structural diagram Outgoing SMS can contain up to 65 characters see Fig 4 5 If sending SMS is impossible ATM...

Страница 40: ...termined as data transmission the modem compares the tele phone number from which the call has been received with the phone numbers enabled in the settings If the number coincides with the enabled one...

Страница 41: ...modem services which require timestamps or compliance with a schedule to operate For example the modem determines time of SMS sending and receiving via RTC and starts the watchdog timers RTC configura...

Страница 42: ...down to the negative supply voltage GND via the 47 k resistor When the pull up is enabled the input is pulled up to the Uin power supply voltage MicroFit 4 connector via the 10 k resistor The encapsu...

Страница 43: ...surement interval number of measurements to be sent In the automatic data transmission mode ATM2 can store up to 150 last values for ADC and 2 last states af ter the change for digital inputs and meas...

Страница 44: ...a absence time option in the ATM Control appli cation after module restart CSD CSD connection is open CSD connection is closed 7 Disabling the module Module is enabled Module is disabled 8 Command mod...

Страница 45: ...is disabled for pins 1 and 2 enabled for pin 3 Only the pulse active state is not stored after restarting the modem the pin is set to the passive state You can disable saving of each pin state in thi...

Страница 46: ...dem version see section GPIO Pins Control via SMS Commands to enter and exit the offline mode see section Offline Mode as well as for single con nection to the server see section Connecting to the Ser...

Страница 47: ...e monitored and controlled from the dispatching center On server modem operation with iRZ Collector see section Monitoring and Control via iRZ Collector In addition the modem features additional funct...

Страница 48: ...s to connect to the modem and its login and password are valid the modem establishes operating connection to a new client and terminates the previ ous connection If the login and password do not match...

Страница 49: ...ode After setting up updating the firm ware the modem returns to the Server mode and opens the port for incoming connections The operation of the server modem with the iRZ Collector server can be set...

Страница 50: ...Settings Basic tab of the ATM Con trol utility 4 19 4 SMS notification on IP Address Change The server modem supports sending of SMS messages to the specified phone number reporting on an IP address...

Страница 51: ...812 318 18 19 E mail support radiofid ru Moscow The company s website www digitalangel ru Phone number in Moscow 7 495 974 74 22 E mail info digitalangel ru Our specialists are always ready to answer...

Отзывы: