Clicking on “
More Information
” opens up a maintenance window that has some further information about the
channel wavelength, indicative power levels and laser/detector temperatures:
Temperature is measured in degrees Celsius.
The power levels are indicative levels as reported by the laser and detector modules. These reading are
approximate, however, to convert these readings to dBm measurements, apply the following formula:
dBm measurement = 10log(Power Reading/10000)
For example, based on the table above,
Channel_01 power reading = 14860.
10log(14860/10000) = 1.72dBm (Tx laser output power level);
Channel_09 power reading = 604.
10log(604/10000) = -12.2dBm (Rx detector input power level).
If the computer mouse is clicked on the blue text,
Index
, the web-browser is directed back to the main window.
C
HANNEL
P
OWER
T
EMPERATURE
W
AVE
L
ENGTH
Channel_01
Tx 14860
43
1610nm
Channel_02
Tx 13111
43
1590nm
Channel_03
Tx 13713
43
1570nm
Channel_04
Tx 14889
43
1550nm
Channel_05
Tx 13430
47
1530nm
Channel_06
Tx 14776
47
1510nm
Channel_07
Tx 13640
46
1490nm
Channel_08
Tx 13550
46
1470nm
Channel_09
Rx 604
44
1450nm
Channel_10
Rx 403
44
1430nm
Channel_11
Rx 527
43
1370nm
Channel_12
Rx 383
43
1350nm
Channel_13
Rx 507
42
1330nm
Channel_14
Rx 529
42
1310nm
Channel_15
Rx 476
43
1290nm
Channel_16
Rx 588
43
1270nm
DTR-1000/8Tx+8Rx+E Version 1.3
IP Address 192.168.1.100
Mac Address FF-FF-FF-FF-FF-FF
Index
More Information