INSTALLATION

 

 

Pre-installation:

 

 

 

Handling: 

 

This equipment contains static sensitive devices and proper static free handling precautions should be observed. 
Do  not  remove  the  lid.  Dangerous  mains  voltage  may  exist  inside  and  service  should  only  be  done  by  qualified 
service personnel. 
 
Where  individual  circuit  cards  are  stored,  they  should  be  placed  in  antistatic  bags.  Proper  antistatic  procedures 
should be followed when inserting or removing cards from these bags. 
 

Power:

 

 

 

AC mains supply:  

AC mains input (PSU 1) is via an IEC mains connector on the rear of the assembly. AC input is 
limited between 90Vac and 264Vac, thus the unit is suitable for all country’s standard mains 
levels without the need for switching between levels. A 1 amp slow blow fuse is fitted in the 
IEC connector in line with the active mains voltage. 

 
DC supply:  

DC  supply  input  is  via  two  DC  locking  jacks  (PSU  2  &  PSU  3)  suitable  for  external  +12Vdc 
power  packs  (50W  minimum  rating)  fitted  with  a  2.1mm  inner  diameter/5.5mm  outer 
diameter  connector  plug  with  a  locking  thread  lock.  The  locking  thread  keeps  the  DC  plug 
securely in place, but is not a necessity for operation. 

 
Any of the three power inlets may be used independently, or together for power supply redundancy. 
 
NOTE: There is no ON/OFF switch. The DTR-1000 will power on as soon as an external power source is applied. 
 

Earthing:

 

 

 

The frame is earthed via the AC mains input signal earth being connected to the chassis. Where a mains earth is 
not present, signal earth is also connected directly to the chassis.  
 
 

Rear Panel – Power/Ethernet Decal Connections:

 

 

The model number is printed on the back of the unit, along with the unit’s serial number, on the Power/Ethernet 
decal, as shown below. For this example, this decal unit’s model number is DTR-1000/12Tx+4Rx+E. Apart from the 
model number, this Power/Ethernet decal is common to all models of DTR-1000. 

 
 

Input Power:

 

 

Input power is via either an IEC power connector (PSU 1) plugged into a 90Vac to 264Vac source, so is suitable for 
all world standards of mains AC power; or via two DC locking jacks (PSU 2 & PSU 3) suitable for ex12Vdc 
power packs (50W minimum rating) fitted with a 2.1mm inner diameter/5.5mm outer diameter DC connector plug 
with  a  locking  thread  lock.  The  locking  thread  keeps  the  DC  plug  securely  in  place,  but  is  not  a  necessity  for 
operation. Any of the three power inlets may be used independently, or together for power supply redundancy. 
 

Control:

 

 

The  Control  connector  is  an  RJ-45  connector  for  CAT-5  twisted  pair  Ethernet  cable.  It  operates  at  10Mbps 
(10base-T) or 100Mbps (100Base-T). It is called a Control port but really it is a Monitoring port. Channel Aliases are, 
however, set via this port. The actual control is via a web-based Ethernet browser addressed to the IP address of 
the unit. The web based browser window will be discussed in 

Operation

 section of this manual. 

 

 

Содержание DTR-1000

Страница 1: ...DTR 1000 I R T Communications Pty Ltd www irtcommunications com Revision 00 Multi Channel 3G HD SD ASI Gigabit Ethernet Fibre Optic Link User Manual...

Страница 2: ...com Page 2 of 19 Revision 00 MULTI CHANNEL 3G HD SD ASI GIGABIT ETHERNET FIBRE OPTIC LINK Revision History Revision Date By Change Description Applicable to 00 19 12 2016 AL Original Issue Firmware ve...

Страница 3: ...installation 10 Power 10 Earthing 10 Rear Panel Power Ethernet Decal Connections 10 Input Power 10 Control 10 Alarm 11 Ethernet 11 Optical 11 Rear Panel Signal Connections 12 DTR 1000 16Tx E DTR 1000...

Страница 4: ...h power ON unless proper precautions are observed All internal adjustments should only be made by suitably qualified personnel All operational adjustments are available externally without the need for...

Страница 5: ...via a single mode Gigabit SFP or 10 Gigabit SFP transceiver operating at 1410nm on one side of the link and 1390nm on the other The optical port uses an internal course wave division multiplexer CWDM...

Страница 6: ...Optical port Web Server Web Server 3G SDI HD SDI SD SDI ASI RJ45 SFP port Ethernet Switch 3G SDI HD SDI SD SDI ASI RJ45 SFP port Ethernet Switch Fibre Link DTR 1000 16Tx E IN 1 IN 2 IN 3 IN 4 IN 5 IN...

Страница 7: ...Web Server Web Server 3G SDI HD SDI SD SDI ASI RJ45 SFP port Ethernet Switch 3G SDI HD SDI SD SDI ASI RJ45 SFP port Ethernet Switch DTR 1000 8Tx E IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 IN 7 IN 8 Tx 1410nm Rx...

Страница 8: ...en fitted with APD detectors standard 0 to 14dB typically 17dB at 3G 19dB at HD and SD when fitted with PIN detectors optional Fibre Link DTR 1000 4Rx 4Tx E OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 O...

Страница 9: ...asers 1270nm to 1610nm 20nm spacing Optical Path Loss 2 3 5 to 21 dB typically 24 dB at 3G SDI 26 dB at HD SD SDI APD detectors 0 to 12 dB typically 15 dB at 3G SDI 17 dB at HD SD SDI PIN detectors Op...

Страница 10: ...power on as soon as an external power source is applied Earthing The frame is earthed via the AC mains input signal earth being connected to the chassis Where a mains earth is not present signal earth...

Страница 11: ...or connection to a corresponding SFP or SPF optical transceiver on a network switch A single mode 1390nm SFP or SFP transceiver is connected on one side of the link and a mode 1410nm SFP or SFP transc...

Страница 12: ...e to be all the same They may be 3G SDI HD SDI SD SDI or ASI types of signals What is transmitted on one channel of one unit is reclocked and received on the corresponding output of the reciprocal uni...

Страница 13: ...E and DTR 1000 8Rx 8Tx E models are designed to operate together as a pair They form an 8 channel forward 8 channel reverse fibre link with bi directional Ethernet DTR 1000 8Tx 8Rx E Rear Panel Signa...

Страница 14: ...The DTR 1000 4Tx 4Rx E and DTR 1000 4Rx TRx E models are designed to operate together as a pair They form a 4 channel forward 4 channel reverse fibre link with bi directional Ethernet DTR 1000 4Tx 4Rx...

Страница 15: ...itter settings display the status of the selected transmitter channel including the channel alias which is set via the embedded web server page Each transmitter channel can be enabled or disabled or t...

Страница 16: ...as01 TransmitAlias02 TransmitAlias03 TransmitAlias08 TransmitAlias04 TransmitAlias05 TransmitAlias06 TransmitAlias07 ReceiverAlias01 ReceiverAlias02 ReceiverAlias03 ReceiverAlias08 ReceiverAlias04 Rec...

Страница 17: ...1 72dBm Tx laser output power level Channel_09 power reading 604 10log 604 10000 12 2dBm Rx detector input power level If the computer mouse is clicked on the blue text Index the web browser is direct...

Страница 18: ...ially important in fibre optic equipment where cleanliness of optical connections is critical to performance When the optical connector is not in use the supplied dust cap should be kept in place Stor...

Страница 19: ...ade with IRT or your local agent to determine whether the equipment can be serviced in the field or should be returned for repair The equipment should be properly packed for return observing antistati...

Отзывы: