15
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
This appliance is approved for installation into a manufactured (mobile)
home. Installation should be in accordance with the Mobile Home Con-
struction and Safety Standard, Title 24 CFR, Part 3280 (in Canada CAN/
CSA Z240 MH), or, when such a standard is not applicable, the Standard
for Mobile Home Installations, ANSI A225.1.
The appliance must be secured to the floor of the fireplace and grounded
to the chassis of the mobile home.
WARNING: DO NOT INSTALL IN SLEEPING ROOM OF A MOBILE
HOME.
CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME
FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED.
Approved Chimney Liner - Flexible or Rigid 6” Stainless Steel 2100ºF HT
Liner listed to UL-1777 (US) or ULC-S635 (Canada).
YOUR CHIMNEY LINER INSTALLATION MUST COMPLY WITH
LOCAL BUILDING AND FIRE CODES.
Outside Combustion Air
In Manufactured (mobile) Home installations, outside combustion air is
required. This can be achieved by sealing the surround assembly to the
fireplace face (and anywhere else that room air may enter the firebox of
the fireplace). A positive flue connection is also required (see instruc-
tions on Page 13
)
. This will ensure combustion air is drawn through the
existing fireplace air duct from outside the house and into the air intake
on the lower back of the appliance.
MANUFACTURED HOME INSTALLATIONS (ML230 ONLY)
Figure 14 - Manufactured (Mobile) Homes
Secure to fireplace floor on
each side using lag screws
Seal the surround to
the fireplace face
Grounded to Steel Chassis
using a #8 AGW copper
wire or equivalent.
A positive flue connection is required in manufactured
home installations (see instructions on Page 13)