ATTACHING SAFETY IN OPERATION WARN-

INGS

Your fireplace has been furnished with safety instruc-

tion labels that are to be affixed to the operation and 

control points of the fireplace.  A safety instruction label 

should be affixed to the receiver wall switch plate where 

the fireplace is turned on and off (See Figure A) and 

the remote control handheld transmitter (Figure B).  

The warnings should already have been put in place 

when the fireplace initial set-up was completed.  If they 

are not affixed at these spots, locate the multi-lingual 

adhesive labels provided with these instructions and 

proceed as follows:

1.  Locate the wall receiver that controls the fireplace 

(verify the switch operates the fireplace by turn-

ing it on and off).  Clean the wall receiver plate 

thoroughly to remove any dust and oils. Affix the 

label to the surface of the plate of the wall receiver  

that controls the fireplace (Figure A).  Choose 

the language primarily spoken in the home. 

2.  Locate the remote control transmitter and clean 

it thoroughly to remove any dust and oils.  Affix 

the label to the surface of handheld transmitter 

(Figure B).  Choose the language primarily spoken 

in the home. 

3.  If you are unable to locate the labels, please 

call Innovative Hearth Products or your nearest 

Innovative Hearth Products dealer to receive 

additional safety instruction labels free of charge.
Cat. No. H8024 Replacement Label Kit 

Innovative Hearth Products

IronStrike.us.com

NOTE: English is red text on clear label. French 

and Spanish are white text on black label.

APPOSITION DES MISES EN GARDE RELATIVES À 

LA SÉCURITÉ D’UTILISATION

Votre foyer a été livré avec des étiquettes de sécurité qui 

doivent être collées à côté des dispositifs de contrôle du 

foyer.  Une étiquette de sécurité devrait être collée sur 

la plaque du récepteur mural contrôlant l’allumage du 

foyer (voir Figure A) et sur le boîtier de la télécommande 

(Figure B).  Les mises en garde auraient dû être collées 

au moment de l’installation initiale du foyer.  Si ce n’est 

pas le cas, prenez les étiquettes adhésives multilingues 

fournies avec ces instructions et procédez comme suit:

1.  Repérez le récepteur mural qui contrôle le foyer 

(vérifiez que l’interrupteur contrôle le fonction-

nement du foyer en le faisant basculer de Marche 

à Arrêt, et vice-versa).  Nettoyez soigneusement la 

plaque du récepteur mural pour éliminer la poussière 

et les traces de graisse ou d’huile. Collez l’étiquette 

sur la surface de la plaque du récepteur mural qui 

contrôle le foyer (Figure A).  Choisissez la langue 

qui est principalement parlée dans la résidence du 

propriétaire. 

2.  Repérez la télécommande et nettoyez-la soigneuse-

ment pour éliminer la poussière et les traces de 

graisse ou d’huile.  Collez l’étiquette sur le boîtier de 

la télécommande (Figure B).  Choisissez la langue 

qui est principalement parlée dans la résidence du 

propriétaire. 

3.   Si vous ne trouvez pas les étiquettes, veuillez appeler 

Innovative Hearth Products ou votre distribu teur 

Innovative Hearth Products local pour recevoir 

gratuitement des étiquettes supplémentaires.
Étiquettes de remplacement, n° cat. H8024 

Innovative Hearth Products

IronStrike.us.com

Remarque : Le texte anglais est rouge sur un support 

transparent. Le texte français et espagnol est blanc 

sur un support noir.

COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD 

EN OPERACIÓN

Su chimenea incluye etiquetas de instrucciones de 

seguridad que deben colocarse en los puntos de 

operación y control de la chimenea. Se debe colocar 

una etiqueta de instrucciones de seguridad en la placa 

del interruptor de pared del receptor desde el cual 

se enciende y se apaga la chimenea (ver la Figura 

A) y en el transmisor de control remoto (Figura B)

Las advertencias ya deben haberse colocado cuando 

se completó la instalación inicial de la chimenea. Si 

no están colocadas en estos lugares, encuentre las 

etiquetas adhesivas multilingües proporcionadas con 

estas instrucciones y prosiga de la siguiente manera:

1.  Identifique el receptor de pared que controla la 

chimenea (verifique que el interruptor opera la 

chimenea encendiéndola y apagándola). Limpie bien 

la placa del receptor de pared para quitar el polvo y 

aceite. Pegue la etiqueta en la superficie de la placa 

del receptor de pared que controla la chimenea 

(Figura A). Seleccione el idioma que más se habla 

en la casa. 

2.  Identifique el transmisor de control remoto y límpielo 

bien para quitar el polvo y aceite. Pegue la etiqueta 

en la superficie del transmisor (Figura B). Seleccione 

el idioma que más se habla en la casa. 

3.  Si no puede encontrar las etiquetas, sírvase llamar 

a Innovative Hearth Products o al distribuidor de 

Innovative Hearth Products más cercano para recibir 

etiquetas de instrucciones de seguridad adicionales 

gratuitas. 
Juego de etiquetas de repuesto - Nº de cat. H8024 

Innovative Hearth Products

IronStrike.us.com

Nota: La etiqueta en inglés es transparente con texto 

rojo. Las etiquetas en francés y español son negras 

con texto blanco.

HOMEOWNER’S INSTRUCTIONS -

 

ATTACHING SAFETY IN OPERATION WARNINGS

SAFETY LABEL DIAGRAMS

DIAGRAMAS DE ETIQUETAS DE 

SEGURIDAD

DIAGRAMMES DES ÉTIQUETTES 

DE SÉCURITÉ

ON

OFF

HI

LO

PILOT

Continuous

Содержание BELLEVUE 27

Страница 1: ...gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety...

Страница 2: ...VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas de contact accidentel avec la vitre chaude et doit tre install pour...

Страница 3: ...o Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio Mantenga la ropa mobiliario gasolina y otros l quidos inflamable...

Страница 4: ...eatures 12 Packaging List 12 Ratings 12 Insert and Fireplace Dimensions 13 Clearances to Combustibles 14 Insert Leveling 14 Installation 15 21 Venting Installation 15 USING THIS MANUAL Please read and...

Страница 5: ...ls viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une ba...

Страница 6: ...r liminerlapoussi re et les traces de graisse ou d huile Collez l tiquette sur la surface de la plaque du r cepteur mural qui contr le le foyer Figure A Choisissez la langue qui est principalement par...

Страница 7: ...Collezl tiquettesurlebo tier de la t l commande Figure B Choisissez la langue qui est principalement parl e dans la r sidence du propri taire En cas de doute collez l tiquette en anglais 3 Si vous ne...

Страница 8: ...anemia those under the influence of alcohol and those at high altitudes Turn off gas and electrical power to the appliance and allow it to cool before cleaning or servicing the appliance If the barri...

Страница 9: ...dition and will void the warranty Please carefully read the sections pertaining to these subjects and or be sure your appliance is properly equipped Never use solid fuels such as wood paper cardboard...

Страница 10: ...l wood burning fireplace listed to UL 127 or ULC S610 only All exhaust gases must be vented outside the structure Combustion air is drawn from outside the structure When installing in a factory built...

Страница 11: ...een tested and certified to ANSI Z21 88 CSA 2 33 Standard for Vented Gas Fireplace Heater and CAN CGA 2 17 M91 and UL 307B Gas Burning Heating Appliances for Manufactured Mobile Homes in both USA and...

Страница 12: ...a specified elevation Only IHP conversion kits can be used to convert from NG to LP or LP to NG Contact your IHP dealer for details PRE INSTALLATION RATINGS Bellevue 27 Bellevue 32 NATURAL GAS LP GAS...

Страница 13: ...Dim Description Bellevue 27 Bellevue 32 A Front Opening Width 27 686mm 32 813mm B Height 18 457mm 19 1 2 495mm C Rear Width 17 432mm 22 559mm D Fireplace Depth 15 381mm 16 406mm Model A B C D E F G H...

Страница 14: ...and the minimum projection of the hearth extension Figure 4 Bellevue 27 32 Clearances MINIMUM CLEARANCES MINIMUM CLEARANCES TO COMBUSTIBLES Bellevue 27 32 A Mantel 32 813mm B Side Wall 4 102mm C Mante...

Страница 15: ...hould be used for correct operation Liner Requirements Use 3 77 mm diameter listed gas vent liner UL1777 ONLY for the EXHAUST Use 3 77 mm diameter listed liner UL 181 or UL1777 for the AIR INTAKE Figu...

Страница 16: ...mm or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship like manner This access hole must be plugged with a non combustible insulation after the gas supply l...

Страница 17: ...the openings on the side mounting brackets on the appliance see Figure 9 Figure 9 A Openings where hooked brackets on Full Front Facade will hang B Side Mounting Brackets on appliance A A B B A A Inst...

Страница 18: ...ure 11 4 Position the separated glowing embers over the small holes on the burner surface Figure 12 Do NOT cover the large burner slots NOTE Enough glowing ember material is provided for several appli...

Страница 19: ...14B Place embers and other media see Page 18 Figure 14A Locate the log placement tabs BV27 Figure 14B Locate the log placement tabs BV32 Figure 15 Place log 1 4 Position the left front log 2 on the le...

Страница 20: ...ave step down regulators to reduce the pressure to safe levels Check the taps for gas leaks with a gas leak test solution retighten if necessary LP and Natural Gas Supplies This appliance is equipped...

Страница 21: ...the adjustment lever side to side see Figure 20 CAUTION The air shutter should never be set so as to make the tips of the flames sooty or create sooting on the viewing glass logs or heat exchanger If...

Страница 22: ...o intermittent mode Tohaveastandingpilotwhichwillhelpstartupduringcoldclimate conditions by warming the flue and the glass switch to standing pilot The standing pilot mode is indicated by a pilot that...

Страница 23: ...cessivetimesfortenminutes each time with a five minute cool down between each firing Ventilate the house during these first firings as the paint gives off an unpleasant odor It is recommended that per...

Страница 24: ...odule Inlet Inlet To Pilot Igniter From Pilot Thermocouple 7 5VDC 1 Amp Adaptor Burner On Off brown Hi Lo blue IPI Cont Pilot yellow Learn black Thermocouple To S Terminal on Main Module Battery Motor...

Страница 25: ...e o Checkthatthechimneyanditsoutletareopenandfreeofsoot block age or debris The venting system should be periodically examined by a qualified agency o Check gaskets once a year Gaskets must be tight R...

Страница 26: ...verse order WARNING Do not attempt to substitute the materials used on these doors or replace cracked or broken glass Handle this glass with extreme care Glass is susceptibletodamage Donotscratchorhan...

Страница 27: ...latest edition or the Canadian Electrical Code Part 1 CSA C22 1 latest edition see Operating Options Figure 23 Page 22 Blower Assembly Fireplace Insert Back Repair If the glass is broken in the glass...

Страница 28: ...ks from the mounting slots on the unit 3 Place the Full Front Facade face down on a soft non abrasive surface to prevent damage 4 Remove barrier from Full Front Facade a Using a 3 8 nut driver remove...

Страница 29: ...TLET VENTS See Firebox Liner Kit and Log Set Installation on Pages 17 19 The main Burner comes on but then goes out Gas is not reaching the appliance Loose wires to the valve or ignition module Pilot...

Страница 30: ...ow RF Control Module F2694 50 Rocker Switch IPI CPI Hi Lo Burner On Off F3182 51 Rocker Switch Momentary Learn F2964 Item Description Cat No 1 Firebox Door Assembly with Glass H9174 2 Gas Train Assemb...

Страница 31: ...31 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS BELLEVUE 27 50 51 18 10 11 14 14 5 8 9 19 20 1 15 6 7 21 16 17 28 41 49 13 40 25 43 32 2...

Страница 32: ...4 14 Full Front Facade Mounting Bracket Kit set of two H9178 15 Refractory Panel Retaining Bracket Kit two sets one of each style J7596 16 90 Elbow Brass 3 8 Tube x 3 8 NPT J7701 17 Battery Holder J79...

Страница 33: ...33 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS BELLEVUE 32 2 50 51 52 40 25 13 49 43 41 16 17 28 10 11 1 5 6 7 8 9 14 15 21 19 14 20...

Страница 34: ...Surround Trimmable 46 W x 38 H Ecoflow Control Kits F2687 EF BRCK Basic Remote Control On Off IPI CPI F2660 EF WWRCK Wireless Wall Switch On Off High Low ON OFF HI LO ON OFF HI LO PILOT Continuous Ba...

Страница 35: ...coflow Control Kits F2687 EF BRCK Basic Remote Control On Off IPI CPI F2660 EF WWRCK Wireless Wall Switch On Off High Low ON OFF HI LO ON OFF HI LO PILOT Continuous Basic Remote Wireless Wall Switch D...

Страница 36: ...ELECTRICAL RATING 120 VAC 60 HZ LESS THAN 2 AMPS CHIMNEY USE 3 76 MM GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777 OR ULC S635 THIS APPLIANCE MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM IN ACCORDAN...

Страница 37: ...610 M 38 101 53 0595 UNIT FACTORY EQUIPPED FOR 0 2000 FT 0 610 M IN CANADA 0 4500 FT 0 1370 M ELECTRICAL RATING 120 VAC 60 HZ LESS THAN 2 AMPS CHIMNEY USE 3 76 MM GAS VENT FLEX CHIMNEY LINER LISTED T...

Страница 38: ...t try to light the pilot by hand B BEFORE OPERATING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHA...

Страница 39: ...cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instruct...

Страница 40: ...ur IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The seri...

Отзывы: