IronStrike BELLEVUE 27 Скачать руководство пользователя страница 25

25

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

CAUTION:  Wear gloves and safety glasses for protection while 

doing required maintenance.

Verify proper operation after servicing.

S'assurer que l'appareil fonctionne adéquatement une fois 

l'entretien terminé.

MAINTENANCE CHECKLIST

The following should only be performed by a qualified service 

technician.

1. Annual inspection should be made and the following checks per-

formed:

 

When unit is cool, remove glass and inspect burner for dirt, soot 

and lint accumulations and remove if necessary. If excessive soot 

accumulation is present on burner, have a qualified service technician 

adjust the burner for proper combustion.

 

Clean inside of glass with gas fireplace glass cleaner. NEVER attempt 

to remove or clean the glass when the unit is hot.

 

Check the hot air outlet vents for lint or other accumulations. Never 

block or restrict vent openings, obstruct flow of ventilation air, or 

use vents other than those approved for use with this appliance.

 

Check that the chimney and its outlet are open and free of soot, block-

age, or debris. The venting system should be periodically examined 

by a qualified agency.

 

Check gaskets once a year. Gaskets must be tight. Replace if neces-

sary.

 

Periodically inspect the pilot system for proper flame. Turn ON the 

IPI switch (Intermittent Pilot Mode, ON [-] = Standing Pilot Mode). 

Ensure the igniter lights the pilot. The pilot flame should engulf the 

flame sensor as shown in Figure 26. See Intermittent/Standing Pilot 

Mode on Page 22 for instructions on switching from intermittent 

ignition to a standing pilot.

 

Periodically inspect the burner flame for proper appearance. See 

Flame Color and Behavior on Page 23.

Check that the area around the insert is kept clear and is free of com-

bustible materials, gasoline and other flammable vapors and liquids.

2. The viewing glass should be cleaned periodically (see Glass Main-

tenance).

MAINTENANCE AND SERVICING

     WARNING 

Turn off gas and electrical power to the fireplace 

and  allow it to cool before cleaning or servicing 

the appliance.

Figure 26 - Proper Pilot Flame Appearance 

Pilot

Hood

Sensor

Ignitor

Igniter

Pilot Hood

Thermocouple

Pilot Hood

Thermocouple

Igniter

Содержание BELLEVUE 27

Страница 1: ...gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety...

Страница 2: ...VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas de contact accidentel avec la vitre chaude et doit tre install pour...

Страница 3: ...o Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio Mantenga la ropa mobiliario gasolina y otros l quidos inflamable...

Страница 4: ...eatures 12 Packaging List 12 Ratings 12 Insert and Fireplace Dimensions 13 Clearances to Combustibles 14 Insert Leveling 14 Installation 15 21 Venting Installation 15 USING THIS MANUAL Please read and...

Страница 5: ...ls viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une ba...

Страница 6: ...r liminerlapoussi re et les traces de graisse ou d huile Collez l tiquette sur la surface de la plaque du r cepteur mural qui contr le le foyer Figure A Choisissez la langue qui est principalement par...

Страница 7: ...Collezl tiquettesurlebo tier de la t l commande Figure B Choisissez la langue qui est principalement parl e dans la r sidence du propri taire En cas de doute collez l tiquette en anglais 3 Si vous ne...

Страница 8: ...anemia those under the influence of alcohol and those at high altitudes Turn off gas and electrical power to the appliance and allow it to cool before cleaning or servicing the appliance If the barri...

Страница 9: ...dition and will void the warranty Please carefully read the sections pertaining to these subjects and or be sure your appliance is properly equipped Never use solid fuels such as wood paper cardboard...

Страница 10: ...l wood burning fireplace listed to UL 127 or ULC S610 only All exhaust gases must be vented outside the structure Combustion air is drawn from outside the structure When installing in a factory built...

Страница 11: ...een tested and certified to ANSI Z21 88 CSA 2 33 Standard for Vented Gas Fireplace Heater and CAN CGA 2 17 M91 and UL 307B Gas Burning Heating Appliances for Manufactured Mobile Homes in both USA and...

Страница 12: ...a specified elevation Only IHP conversion kits can be used to convert from NG to LP or LP to NG Contact your IHP dealer for details PRE INSTALLATION RATINGS Bellevue 27 Bellevue 32 NATURAL GAS LP GAS...

Страница 13: ...Dim Description Bellevue 27 Bellevue 32 A Front Opening Width 27 686mm 32 813mm B Height 18 457mm 19 1 2 495mm C Rear Width 17 432mm 22 559mm D Fireplace Depth 15 381mm 16 406mm Model A B C D E F G H...

Страница 14: ...and the minimum projection of the hearth extension Figure 4 Bellevue 27 32 Clearances MINIMUM CLEARANCES MINIMUM CLEARANCES TO COMBUSTIBLES Bellevue 27 32 A Mantel 32 813mm B Side Wall 4 102mm C Mante...

Страница 15: ...hould be used for correct operation Liner Requirements Use 3 77 mm diameter listed gas vent liner UL1777 ONLY for the EXHAUST Use 3 77 mm diameter listed liner UL 181 or UL1777 for the AIR INTAKE Figu...

Страница 16: ...mm or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship like manner This access hole must be plugged with a non combustible insulation after the gas supply l...

Страница 17: ...the openings on the side mounting brackets on the appliance see Figure 9 Figure 9 A Openings where hooked brackets on Full Front Facade will hang B Side Mounting Brackets on appliance A A B B A A Inst...

Страница 18: ...ure 11 4 Position the separated glowing embers over the small holes on the burner surface Figure 12 Do NOT cover the large burner slots NOTE Enough glowing ember material is provided for several appli...

Страница 19: ...14B Place embers and other media see Page 18 Figure 14A Locate the log placement tabs BV27 Figure 14B Locate the log placement tabs BV32 Figure 15 Place log 1 4 Position the left front log 2 on the le...

Страница 20: ...ave step down regulators to reduce the pressure to safe levels Check the taps for gas leaks with a gas leak test solution retighten if necessary LP and Natural Gas Supplies This appliance is equipped...

Страница 21: ...the adjustment lever side to side see Figure 20 CAUTION The air shutter should never be set so as to make the tips of the flames sooty or create sooting on the viewing glass logs or heat exchanger If...

Страница 22: ...o intermittent mode Tohaveastandingpilotwhichwillhelpstartupduringcoldclimate conditions by warming the flue and the glass switch to standing pilot The standing pilot mode is indicated by a pilot that...

Страница 23: ...cessivetimesfortenminutes each time with a five minute cool down between each firing Ventilate the house during these first firings as the paint gives off an unpleasant odor It is recommended that per...

Страница 24: ...odule Inlet Inlet To Pilot Igniter From Pilot Thermocouple 7 5VDC 1 Amp Adaptor Burner On Off brown Hi Lo blue IPI Cont Pilot yellow Learn black Thermocouple To S Terminal on Main Module Battery Motor...

Страница 25: ...e o Checkthatthechimneyanditsoutletareopenandfreeofsoot block age or debris The venting system should be periodically examined by a qualified agency o Check gaskets once a year Gaskets must be tight R...

Страница 26: ...verse order WARNING Do not attempt to substitute the materials used on these doors or replace cracked or broken glass Handle this glass with extreme care Glass is susceptibletodamage Donotscratchorhan...

Страница 27: ...latest edition or the Canadian Electrical Code Part 1 CSA C22 1 latest edition see Operating Options Figure 23 Page 22 Blower Assembly Fireplace Insert Back Repair If the glass is broken in the glass...

Страница 28: ...ks from the mounting slots on the unit 3 Place the Full Front Facade face down on a soft non abrasive surface to prevent damage 4 Remove barrier from Full Front Facade a Using a 3 8 nut driver remove...

Страница 29: ...TLET VENTS See Firebox Liner Kit and Log Set Installation on Pages 17 19 The main Burner comes on but then goes out Gas is not reaching the appliance Loose wires to the valve or ignition module Pilot...

Страница 30: ...ow RF Control Module F2694 50 Rocker Switch IPI CPI Hi Lo Burner On Off F3182 51 Rocker Switch Momentary Learn F2964 Item Description Cat No 1 Firebox Door Assembly with Glass H9174 2 Gas Train Assemb...

Страница 31: ...31 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS BELLEVUE 27 50 51 18 10 11 14 14 5 8 9 19 20 1 15 6 7 21 16 17 28 41 49 13 40 25 43 32 2...

Страница 32: ...4 14 Full Front Facade Mounting Bracket Kit set of two H9178 15 Refractory Panel Retaining Bracket Kit two sets one of each style J7596 16 90 Elbow Brass 3 8 Tube x 3 8 NPT J7701 17 Battery Holder J79...

Страница 33: ...33 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS BELLEVUE 32 2 50 51 52 40 25 13 49 43 41 16 17 28 10 11 1 5 6 7 8 9 14 15 21 19 14 20...

Страница 34: ...Surround Trimmable 46 W x 38 H Ecoflow Control Kits F2687 EF BRCK Basic Remote Control On Off IPI CPI F2660 EF WWRCK Wireless Wall Switch On Off High Low ON OFF HI LO ON OFF HI LO PILOT Continuous Ba...

Страница 35: ...coflow Control Kits F2687 EF BRCK Basic Remote Control On Off IPI CPI F2660 EF WWRCK Wireless Wall Switch On Off High Low ON OFF HI LO ON OFF HI LO PILOT Continuous Basic Remote Wireless Wall Switch D...

Страница 36: ...ELECTRICAL RATING 120 VAC 60 HZ LESS THAN 2 AMPS CHIMNEY USE 3 76 MM GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777 OR ULC S635 THIS APPLIANCE MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM IN ACCORDAN...

Страница 37: ...610 M 38 101 53 0595 UNIT FACTORY EQUIPPED FOR 0 2000 FT 0 610 M IN CANADA 0 4500 FT 0 1370 M ELECTRICAL RATING 120 VAC 60 HZ LESS THAN 2 AMPS CHIMNEY USE 3 76 MM GAS VENT FLEX CHIMNEY LINER LISTED T...

Страница 38: ...t try to light the pilot by hand B BEFORE OPERATING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHA...

Страница 39: ...cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instruct...

Страница 40: ...ur IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The seri...