background image

15510-EN Rev G 

Safety and Compliance   35

Labels

NOTE:  The actual label may vary with laser model.

Serial Number 

(rear panel)

 

Ground 

(bottom of laser)

Footswitch

Responsibility for Validation and Fitness-of-Use:
Because Valmark Industries, Inc. has no controlover the use or application of 
these parts, it is the sole responsibility of the OEM customer and/or its designated 
manufacturer to test all custom parts for fitness-of-use and validation of design 
prior to acceptance of production units.  Valmark Industries provides expertise in 
the layout and consistent fabrication of high quality, reliable membrane switch, 
custom graphics and labeling products.  Valmark and its employees do NOT 
purport to be experts in the end-use application of our customers, or the 
environments in which these products will be stored and/or used.  

THIS PRINT MUST BE APPROVED AND RETURNED WITHIN 24 
HOURS IN ORDER FOR THIS JOB TO PROCEED WITH 
PRODUCTION. ACCEPTANCE OF THE BELOW ART SAMPLE 
RELEASES VALMARK OF ANY GRAPHICS LIABILITY AFTER THE 
PRODUCTION RUN. (1) Valmark may, at its discretion unless 
otherwise noted, substitute  any materials or BOM components 
with equivalent or similar materials and/or components based on 
control of cost or availability

APPROVAL PRINT

RESUBMIT WITH

CORRECTIONS

APPROVED WITH

CORRECTIONS

OK AS IS

APPROVAL

SIGNATURE

DATE

APPROVAL PRINT

Customer Supplied Prints

Part Number

Date

Dimensional

Graphics

Modifications

Description

ECO #

Rev.

Date

NOTES:

CONSTRUCTION:

1

LABEL PERIPHERY (keyline does not print)

2

BACKGROUND: BLACK

3

GRAPHICS: Blue PMS 285C

4

GRAPHICS: WHITE

31602

LABEL P/N: 31792-2F

0086

110001R

LABEL P/N: 31792-1F

0086

1212 Terra Bella Avenue

Mountain View, CA 94043 USA

Tel: 650-940-4700

Fax: 650-940-4710

www.iridex.com

MADE IN THE USA

REF

SN

31602
110001F

FCC ID: UDB31539

IC ID: 6590A-31539

Emergo Europe

Molenstraat 15

2513 BH The Hague

The Netherlands

Tel:(31) (0) 70 345-8570

Fax: (31) (0) 70 346-7299

EC REP

®

3

CENTER GRAPHICS

PART NUMBER:

GRAPHIC OVERLAY

DW

01/03/17

31792

F

IRIDEX

REV:

CUSTOMER:

DATE:

DATE:

1 OF 1

1:1

TOLERANCE:

UNLESS OTHERWISE SPECIFIED

DIMENSIONS ARE IN INCHES

THIRD ANGLE PROJECTION

SHEET:

SCALE:

TITLE:

APP BY:

DR BY:

Fax (925) 960-0900

Phone (925) 960-9900

www.nidec-vis.com

7900 National Dr. Livermore, CA 94550

.XX  ±0.01” 

.XXX  ±0.010”

DECIMALS

TOOLING:

ANGLES
±0.5º

.XX  ±0.02” 

.XXX  ±0.015”

±0.5º

DECIMALS

GRAPHICS:

ANGLES

3M 468

.010 8B35

BASE MATERIAL

ADHESIVE 

Wireless Receiver

Responsibility for Validation and Fitness-of-Use:
Because Valmark Industries, Inc. has no controlover the use or application of 
these parts, it is the sole responsibility of the OEM customer and/or its designated 
manufacturer to test all custom parts for fitness-of-use and validation of design 
prior to acceptance of production units.  Valmark Industries provides expertise in 
the layout and consistent fabrication of high quality, reliable membrane switch, 
custom graphics and labeling products.  Valmark and its employees do NOT 
purport to be experts in the end-use application of our customers, or the 
environments in which these products will be stored and/or used.  

THIS PRINT MUST BE APPROVED AND RETURNED WITHIN 24 
HOURS IN ORDER FOR THIS JOB TO PROCEED WITH 
PRODUCTION. ACCEPTANCE OF THE BELOW ART SAMPLE 
RELEASES VALMARK OF ANY GRAPHICS LIABILITY AFTER THE 
PRODUCTION RUN. (1) Valmark may, at its discretion unless 
otherwise noted, substitute  any materials or BOM components 
with equivalent or similar materials and/or components based on 
control of cost or availability

APPROVAL PRINT

RESUBMIT WITH

CORRECTIONS

APPROVED WITH

CORRECTIONS

OK AS IS

APPROVAL

SIGNATURE

DATE

APPROVAL PRINT

Customer Supplied Prints

Part Number

Date

Dimensional

Graphics

Modifications

Description

ECO #

Rev.

Date

NOTES:

CONSTRUCTION:

1

LABEL PERIPHERY (keyline does not print)

2

BACKGROUND: BLACK

3

GRAPHICS: Blue PMS 285C

4

GRAPHICS: WHITE

31602

LABEL P/N: 31792-2F

0086

110001R

LABEL P/N: 31792-1F

0086

1212 Terra Bella Avenue

Mountain View, CA 94043 USA

Tel: 650-940-4700

Fax: 650-940-4710

www.iridex.com

MADE IN THE USA

REF

SN

31602
110001F

FCC ID: UDB31539

IC ID: 6590A-31539

Emergo Europe

Molenstraat 15

2513 BH The Hague

The Netherlands

Tel:(31) (0) 70 345-8570

Fax: (31) (0) 70 346-7299

EC REP

®

3

CENTER GRAPHICS

PART NUMBER:

GRAPHIC OVERLAY

DW

01/03/17

31792

F

IRIDEX

REV:

CUSTOMER:

DATE:

DATE:

1 OF 1

1:1

TOLERANCE:

UNLESS OTHERWISE SPECIFIED

DIMENSIONS ARE IN INCHES

THIRD ANGLE PROJECTION

SHEET:

SCALE:

TITLE:

APP BY:

DR BY:

Fax (925) 960-0900

Phone (925) 960-9900

www.nidec-vis.com

7900 National Dr. Livermore, CA 94550

.XX  ±0.01” 

.XXX  ±0.010”

DECIMALS

TOOLING:

ANGLES
±0.5º

.XX  ±0.02” 

.XXX  ±0.015”

±0.5º

DECIMALS

GRAPHICS:

ANGLES

3M 468

.010 8B35

BASE MATERIAL

ADHESIVE 

Remote Control

1
2

3
4

PMS 285C BLUE LOGO

GRAPHICS:  WHITE

BACKGROUND:  BLACK

LABEL PERIPHERY - DOES NOT PRINT

LAMINATION:

.005 LEXAN

C

65891

IPX1

65891C

RC0100

65777

IQ Family Remote Control

Responsibility for Validation and Fitness-of-Use:
Because Valmark Industries, Inc. has no controlover the use or application of 
these parts, it is the sole responsibility of the OEM customer and/or its designated 
manufacturer to test all custom parts for fitness-of-use and validation of design 
prior to acceptance of production units.  Valmark Industries provides expertise in 
the layout and consistent fabrication of high quality, reliable membrane switch, 
custom graphics and labeling products.  Valmark and its employees do NOT 
purport to be experts in the end-use application of our customers, or the 
environments in which these products will be stored and/or used.  

THIS PRINT MUST BE APPROVED AND RETURNED WITHIN 24 
HOURS IN ORDER FOR THIS JOB TO PROCEED WITH 
PRODUCTION. ACCEPTANCE OF THE BELOW ART SAMPLE 
RELEASES VALMARK OF ANY GRAPHICS LIABILITY AFTER THE 
PRODUCTION RUN. (1) Valmark may, at its discretion unless 
otherwise noted, substitute  any materials or BOM components 
with equivalent or similar materials and/or components based on 
control of cost or availability

APPROVAL PRINT

RESUBMIT WITH

CORRECTIONS

APPROVED WITH

CORRECTIONS

OK AS IS

APPROVAL

SIGNATURE

DATE

IRIDEX

APPROVALS

DATE

DRW

DW

08/08/14

COMPANY (OEM)

SCALE

PART NO.

1 : 1

REV

MANUFACTURERS:

SHEET 1 of 1

CHK

DSN

ENGR

THIRD ANGLE

PROJECTION

UNLESS OTHERWISE SPECIFIED, UNITS

ARE IN INCHES.  TOLERANCES:

INTERPRET DRAWING PER

ANSI Y14.5M - - 1994

DO NOT SCALE DRAWING

Customer Supplied Prints

Part Number

Date

Dimensional

Graphics

Modifications

Description

ECO #

Rev.

Date

NOTES:

CONSTRUCTION:

BASE MATERIAL

ADHESIVE - 

FULL

PERM

.XX  ±0.01” 

.XXX  ±0.010” 

TOOLING:

ANGLES

±0.5º

.XX  ±0.02” 

.XXX  ±0.015” 

CUT TO GRAPHICS:

ANGLES

±0.5º

Valmark Interface Solutions

A Nidec Kinetek Company

®

3M 7871 0.002 Gloss White 

TT PET #350 LSE

Содержание IQ 532

Страница 1: ...IRIDEX IQ 577 IQ 532 Laser Systems Operator Manual...

Страница 2: ...OcuLight EndoProbe and SmartKey are registered trademarks BriteLight CW Pulse DioPexy EasyFit EasyView FiberCheck FlexFiber G Probe IQ 532 IQ 577 IQ 810 LongPulse MicroPulse MilliPulse OtoProbe Power...

Страница 3: ...Using the Laser System 17 4 Troubleshooting 24 General Problems 24 Error Messages 26 5 Maintenance 29 Inspecting and Cleaning the Laser 29 Inspecting and Cleaning the Footswitch 29 Verifying the Power...

Страница 4: ...Contents iv 15510 EN Rev G...

Страница 5: ...ry devices are compatible with the IQ 577 and IQ 532 laser systems TxCell Scanning Laser Delivery System EndoProbe handpiece Slit Lamp Adapters SLA Laser Indirect Ophthalmoscopes LIO ENT Delivery Devi...

Страница 6: ...changes because MicroPulse laser delivery is being used instead of CW and The total laser energy of such doses is only a percentage often chosen by clinicians to be 20 70 of that energy needed to prod...

Страница 7: ...inclusive and is not intended to replace surgeon training or experience The regulatory information provided is applicable only in the United States If you use the laser for indications not included he...

Страница 8: ...detachment Specific to laser trabeculoplasty IOP spike and disruption of the corneal epithelium Specific Warnings and Precautions It is essential that the surgeon and attending staff be trained in al...

Страница 9: ...cations for Use IQ 532 Models This section provides information on the use of the laser in clinical specialties Information is provided by specialty and includes procedural recommendations along with...

Страница 10: ...tinal photocoagulation and intravitreal endophotocoagulation of vascular and structural abnormalities of the retina and choroids including Proliferative and nonproliferative diabetic retinopathy Choro...

Страница 11: ...n Ignition or perforation of endotracheal tubes by the laser beam could result in serious or fatal patient complications Use the lowest possible oxygen concentration to support the patient Use the ven...

Страница 12: ...the patient s medical and wound healing history If uncertain of expected clinical response always start with a conservative setting and increase the setting in small steps 532 nm Typical Laser Treatm...

Страница 13: ...1000 2500 20 100 Control of Bleeding N A 200 2500 20 100 Spot size at target is dependent on many parameters including fiber core diameter and working distance Laryngology Treatment Delivery Device Sp...

Страница 14: ...ht reflective surfaces Avoid directing the treatment beam at highly reflective surfaces such as metal instruments Ensure that all personnel in the treatment room are wearing the appropriate laser safe...

Страница 15: ...blems with materials or workmanship This warranty is void if service is attempted by anyone other than certified IRIDEX service personnel WARNING Use only IRIDEX delivery devices with the IRIDEX laser...

Страница 16: ...IRIDEX Customer Service Representative if there are problems with your order Appearance and type of components may vary based on the system ordered Laser also Console Operator Manual not shown Power...

Страница 17: ...cord included in the packaging is appropriate for your location Always use an approved three wire grounding cord set Do not alter the power inlet To ensure proper grounding follow local electrical co...

Страница 18: ...PPROVAL PRINT E PN 65893 Rev E 010 8B35 3M468 MP CUT THROUGH AREAS 8X GRAPHICS WHITE BLACK TEXT WITH PMS YELLOW C FIELD BACKGROUND BLACK PMS 285C BLUE LOGO OTES CONSTRUCTION BASE MATERIAL ADHESIVE GRA...

Страница 19: ...position To turn the laser off turn the key to the Off position Remove and store the key to prevent unauthorized use NOTE The key can be removed in the Off position only In an emergency press the red...

Страница 20: ...llary personnel in the treatment room are wearing the appropriate laser safety eyewear 7 Select Treat mode 8 Position the aiming beam on the treatment site 9 Focus or adjust the delivery device as app...

Страница 21: ...Interface A Touchscreen Interface Displays current parameter and functions and acts as the interface to select screens or parameters B Control knobs Used to adjust parameters on the screen C Laser bu...

Страница 22: ...l fire when footswitch is pressed Standby Laser is disengaged Treat Laser is firing footswitch pressed H Aiming Beam and LIO adjustments I Displays pulse duration Adjust with control knob J Displays p...

Страница 23: ...een MicroPulse Settings Optional A Turn MicroPulse ON or OFF B Select preset values for Duty Cycle MicroPulse duration and Interval parameters update automatically C Displays MicroPulse duration and i...

Страница 24: ...the Preset Menu at the Standby screen touch PRESETS A Programmable presets B Selection button to load highlighted preset and go to Standby screen C Cancel loading preset selection and return to Stand...

Страница 25: ...Pulse settings C Use control knobs to select pulse duration power and interval D Displays Preset name Press to enter Keyboard mode E Save changes and return to Treat screen F Discard changes and retur...

Страница 26: ...rs 0 to 9 Do NOT use any symbols Symbols may generate a warning message Aux Device Required when a TxCell Scanning Laser Delivery System is subsequently connected to the laser console If this error oc...

Страница 27: ...h laser settings C Set voice prompt Female Male OFF Use only when adjusting power with footswitch D Set Auxiliary ON in Standby or ON in Treat Operate a warning light or auditory signal outside the tr...

Страница 28: ...e No treatment beam Verify that the remote interlock has not been activated Verify that the aiming beam is visible Verify that the fiber switch is in the correct position for the laser system and wave...

Страница 29: ...e response threshold for consistent response Increase the laser power and or exposure duration or select a different lens Does not fit on the mounting plate OMA only Inspect and clean the mounting pla...

Страница 30: ...essed Turn key off for 5 seconds then on E00701 System controller watchdog failure E01003 E01009 System needs calibration E03002 E03003 Invalid sensor reading E03010 E03020 E03040 Laser temperature in...

Страница 31: ...e If installed on a room door close door to proceed E05035 Laser safety eye filter not in position System detected out of position filter while attempting to treat Verify that SmartKey is connected If...

Страница 32: ...03 Missing Pulse error System unable to deliver laser pulse when it was expected Check connections and turn laser key OFF for 5 seconds then back ON W0001 Verify a 577 nm eye safety filter is in place...

Страница 33: ...ay laser light to transmit WARNING Do not remove covers Removing covers and shields may result in exposure to dangerous optical radiation levels and electrical voltages Only IRIDEX trained personnel m...

Страница 34: ...mage the power meter sensor 4 Set the laser Duration to 3000 ms and the Interval to Single Pulse when a CW delivery device is connected Set the Duration to 3000 ms MicroPulse Duration to 1 0 ms and Mi...

Страница 35: ...del and Serial Number _______________ Calibrated by _______________ Power Measurements using a MicroPulse Delivery Device Exposure Duration ms MicroPulse Duration ms MicroPulse Interval ms Indicated P...

Страница 36: ...ions not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Protection for the Physician Eye safety filters protect the physician from...

Страница 37: ...resulting in unique NOHD values for each delivery device NOTE Not all delivery devices are available for all laser models IQ 577 IQ 532 NOHD Values for Various Delivery Devices Delivery Device MPE W...

Страница 38: ...Standby light provides a visible warning that laser radiation is accessible When Treat mode is selected a three second delay prevents unintentional laser exposure The console delivers laser energy onl...

Страница 39: ...MALS GRAPHICS ANGLES 3M 468 010 8B35 BASE MATERIAL ADHESIVE Wireless Receiver PRINT MUST BE APPROVED AND RETURNED WITHIN 24 RS IN ORDER FOR THIS JOB TO PROCEED WITH DUCTION ACCEPTANCE OF THE BELOW ART...

Страница 40: ...514 AP The Hague The Netherlands LASER RADIATION AVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION CLASS 4 LASER PRODUCT CLASS 2 LASER PRODUCT IEC 60825 1 2007 2014 RAYONNEMENT LASER EXPOSIT...

Страница 41: ...witch Footswitch In Footswitch Out Fuse Gauge Protective Earth Ground Illuminating Probe Decrease Increase Interval Interval with MicroPulse Laser Aperture at End of Fiber Laser Warning Illumination L...

Страница 42: ...aser Firing Laser Preparing Speaker Screen System Brightness Latex Free Prescription Warning Replace with fuses as indicated Specifications Specification Description Treatment wavelength IQ 577 577 nm...

Страница 43: ...al 100 240 VAC 50 60 Hz 3 A Cooling Air cooled Operating temperature range 10 C to 35 C 50 F to 95 F Storage temperature range 20 C to 60 C 4 F to 140 F Relative humidity 20 to 80 non condensing Dimen...

Страница 44: ...y linked and will not work with other IRIDEX footswitches or similar components Clearly identify each pair to prevent separation of the linked components NOTE The footswitch is designed to operate wit...

Страница 45: ...ission frequency range The wireless footswitch has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provid...

Страница 46: ...ronment Emissions Test Compliance RF emissions CISPR 11 Group 1 The laser system uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any i...

Страница 47: ...1000 4 5 1 kV differential mode 2 kV common mode 1 kV differential mode 2 kV common mode Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interrupt...

Страница 48: ...eters m a Fields strengths from fixed RF transmitters as determined by an electromagnetic site survey should be less than the compliance level in each frequency range b Interference may occur in the v...

Страница 49: ...mum Output Power of Transmitter W Separation Distance According to Frequency of Transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 3...

Отзывы: