Change the System Setting — Digital I/O.
Please follow the steps below to change the Digital I/O through the network if necessary.
1. Click
the
Digital I/O
button on the left side of the “System” page to enter the “Digital I/O Setting”
page.
2.
:
Select form the drop-down list to set the details of each channel.
3.
Mark the “Digital Input” “ON” or “OFF”. Click your choices to enable.
4.
Select from the drop-down list to modify the Active Type of the Digital Input or Digital Output.
5. Click
the
Submit
button to submit the new user’s setting.
6. Click
the
Home
button to return to the home page.
Description of function keys:
Digital Input:
Select “ON” or “OFF” to use the GPIO connector or shut it down.
Digital Output:
Use the GPIO connector.
Note:
For using the Digital Output function, you have to set the driven type of the alarm device. The
Video Server provides two choices between High or Low. When setting the alarm device input to
high level or activating the rising edge, please set the Digital Output function to High, otherwise,
please set to Low.