2.1 Mounting Configuration
Install the necessary accessories in sequence using
Figure 2
as a guide. An Air Control Valve
(K) for Controlling air flow is required with the equipment. To minimize the risk of serious bodily
injury such as splashing fluid on the skin or in the eyes; or risk of injury from moving parts,
install the following accessories in your system.
1.
Bleed-off master air valve (D)
This valve will relieve the air trapped within the system after the pump is stopped. Air
that is trapped between this valve and the pump can cause the pump to reciprocate
unintentionally, which may cause harm to the operator.
2.
Fluid Drain Valve (G)
The fluid drain valve (use a metal valve for grounding purposes) is installed to relieve
fluid pressure in the pump, hose or the dispensing valve when the pump is stopped. The
relief of pressure by the dispensing valve, which at times is inadequate if there is a clog
or restriction in the hose or the dispensing valve, can be achieved by using the fluid
drain valve (G).
3.
Low level cut-off valve or runaway safety valve
The low level cut-off valve should be installed at the fluid intake port of the pump. It
shuts off the fluid intake when the fluid level is too low, causing the pump to stall. This is
to prevent the pump from running empty. If not, then a runaway safety valve should be
installed. This valve shuts off the air supply to the pump if the pump accelerates beyond
the pre-set value when the fluid level is too low and the pump is pumping air, or there is
insufficient fluid for normal pump operation.
Connect an air lubricator (C). The lubricator provides proper lubrication to the air motor. (see
daily maintenance check). Next, install a bleed-off master air valve (D). This valve is required
in your system to relieve trapped air (as explained above).
Air Filter (E) helps to remove dirt and foreign particles from the supply air, water moisture also
will be trapped within this filter. Be sure to release the trapped water daily as a good
housekeeping practice (Also see daily maintenance check). Connect a grounded air supply
hose for the supply of air.
For the fluid section, connect one fluid drain valve (G) directly after the outlet of the pump. Be
sure to connect it pointing downwards for safety. Connect a grounded fluid hose (M) to the fluid
outlet 3/4” NPTF.
Grounding of the pump and accessories are to be ensured before operation. Observe all
OSHA regulations and other safety regulations.
Содержание IP-02S
Страница 19: ...19 5 3 Parts drawing for IP 02 Fluid Section for C Steel Drum Length ...
Страница 21: ...21 5 5 Parts drawing for IP 02SST Fluid Section for S Steel Drum Length ...
Страница 23: ...23 5 7 Parts drawing for IP 02S Fluid Section for C Steel Stubby ...
Страница 25: ...25 5 9 Parts drawing for IP 02S SST Fluid Section S Steel Stubby ...
Страница 30: ...30 ...