109
YLS-K
Command
Parameter 1 Parameter 2 Comment
#
Name
4
WAIT
SI
LOW
Wait for LOW (0) level sig-
nal on input Sync. IN.
SI
HIGH
Wait for HIGH (1) level sig-
nal on input Sync. IN.
SI
LH
Wait for rising edge on input
Sync. In.
SI
HL
Wait for falling edge on in-
put Sync. IN.
Time
0 – 655000
or FBUS
Wait time in ms
5
GOTO
Line 0 - 99
SI LOW
Jumps to the next line of the
program as long as a LOW
(0) level signal is present at
SI.
Line 0 - 99
SI HIGH
Jumps to the next line of the
program as long as a HIGH
(1) level signal is present at
SI.
Line 0 - 99
0 - 32000
Jumps to the specified line
as often specified in parame-
ter 2.
6
OUT
SO
LOW
Sets signal LOW (0) at out-
put Sync. OUT.
SO
HIGH
Sets signal HIGH (1) at out-
put Sync. OUT.
7
EXTPWR
ANALOG
-
Changes to the analog inter-
face
FBUS
-
Changes to the fieldbus in-
terface
8
SETCHAN
Channel 1 …
n
-
Selection of the optical chan-
nel for production with inte-
grated beam switch (only
available in command line 1)
Table 18:
Modules tab description
| LaserNet software