iPECS eMG80
System DECT Installation Guide
Issue 1.3
13
Figure 3.2.4-3 Base Station Aligned with Corridor to Adjoining Area
CAUTION
1.
The appropriate position for a Base Station is no closer than 1.8m above the floor
and 0.5m below the ceiling.
- The best communication environment is when a Base Station and a user are of
the same height. In an office environment, however, it is recommended to
consider office furniture (especially iron desktops or cabinets) to minimize
reflection, diffraction and scattering of DECT wave when you set the position of a
Base Station.
2.
Keep away from any electronic equipment such as copy machines, printers or
computers.
3.
The lower wall of a corridor where many people pass by, corner of a wall, and
narrow indoors also should be avoided.
4.
When you install a Base Station on the wall, it is better to include intervals.
- DECT wave is attenuated by reflection indoors. In order to minimize attenuation,
when you install a Base Station on the wall, give at least three-wave-length
intervals. The intervals should be about 45cm because the wavelength is 15cm at
DECT frequency.
In iPECS eMG80 System, WTIB4 is Base Station interface board. iPECS eMG80 System can
have one WTIB4 (up to 4 ports).