iPECS eMG80/100 & eMG800 & UCP
User Portal User Guide
Issue 1.4
20
9.1
Station Attributes
Selecting Station Attributes will be displayed the input entry page. Click [Save] button after changing Value
each attribute to apply.
Figure 8.1-1 Station Attributes
Station Attributes define features and functions available to the station. Refer to the following table for a brief
description of the features and the input required.
Attributes
Description
Range
Default
DND
Enables DND to be activated by the station. The station can be
limited to activate DND for outside calls (CO/IP Only) or for
internal calls (ICM only), if desired.
OFF, ALL, ICM call only, CO call only
Refer to
description
OFF
ICM Signaling
Mode
The user may select Hands-free (H), Privacy (P) or Tone Ring
(T) for the ICM Signaling mode.
H, T, P
T
Call Coverage
Mode
The Call Coverage feature permits an iPECS Phone user to
receive ring and answer calls for other stations.
OFF
ON
OFF
Delay Ring
Cycle
When a covered station rings, the
{CALL COVERAGE}
button
LED will flash at the covering station and the station will receive
ring (immediate or delayed, 0 to 15 ring cycles).
0~15
0
Headset Usage
The user may enable iPECS IP or LDP series phone for use
with Headset.
OFF
ON
OFF
Authorization
Code
Authorization codes are employed to control access to the
system resources and facilities. Walking COS, CO/IP Group
access DISA callers and certain Call Forward types may
require the input of a valid Authorization code.
Codes up to 12 digits may be entered.
Max. 12
digit
(Include *)
N/A