Operating and mounting instructions 

 

PowerBlock io64                                                                      Order number: 77024-180-03  

 

BMA 77024-io64_Rev1_en 

1/7 

 

General usage 

 
Power Block series consists of 2 different actuator types. It can be installed in a standard distribution board. 
 

 

4TE DIN Rail casing modules for 8 outputs 

 

8TE DIN Rail casing modules for 16 outputs 

 
 A brief overview of the functionality is given in the following table:  
 

 
 

 
 

Device type and accessories 

 
At present the following device types are available in the PowerBlock control group: 
 

Product  

 

Description 

 

 

 

 

 

 

Order number: 

Power Block o8   

  8 capacitive outputs  

 

 

 

 

 

77024-180-01 

Power Block o16   

16 capacitive outputs 

 

 

 

 

 

77024-180-02 

Power Block io64  

  4 capacitive outpus and 6 analog / digital inputs 

 

 

77024-180-03 

 

Scope of delivery 

 
The following individual components are included in the delivery of the PowerBlock device: 
 

Complete device with connected bus connector 

Operating and mounting instructions 

Delivered in break-proof individual packaging 

 

Application programs 

 
The following application programs are currently available for the PowerBlock device: 
 

77014-PowerBlock io64-11-0110 

 

Installation device 

 

 

Risk of death by electric shock.  

 

The device is intended for interior installation in dry rooms.  

 

The device must only be installed and commissioned by an accredited electrical engineer.  

 

Please follow country-specific safety and accident prevention rules as well as all current KNX guide lines.  

 

Please follow country-specific rules and regulations for the planning and construction of installations, especially 
with regard to emergency lighting systems.  

 

For the installation the device must be switched to zero potential.  

 

Do not open the device! Faulty devices must be returned to the manufacturer.  

 
 

Outputs  
BINARY ( POWER LEDs SUPPORTED) 

SHUTTER / BLIND 

Bus failure 

Bus failure 

Central ON/OFF 

Scenes 

Counters 

Presets 

Scenes 

Alarms 

Timers 

Disable funktion 

Alarms 

Manual control 

Disable function 

 

Manual control 

 

ADVANCED FUNCTIONS 
Analog & digital alarms 

Logic functions 

Scene controller 

Advanced scene controller 

Timers 

Setpoints 

Overwrite end user parameters 

Behavior at bus recovery 

Содержание Power Block Series

Страница 1: ...packaging Application programs The following application programs are currently available for the PowerBlock device 77014 PowerBlock io64 11 0110 Installation device Risk of death by electric shock T...

Страница 2: ...m 0 5 Nm Number of inputs Total inputs 6 binary analog mixed inputs with 2 common terminals Art der Eing nge Binary Analog Ready for Dry contacts Standard movement detector with dry contact output Sen...

Страница 3: ...boxes on 35 mm DIN rails and wall boxes 5 4 6 2 6 1 2 1 3 8 72mm 4 DIN RAIL 7 1 7 2 1 KNX bus connector 2 Programming button 3 Programming LED 4 SD card slot only for internal use 5 Outputs connector...

Страница 4: ...e are labelled clearly The power supply is connected to the bottom right hand side connector according to the order indicated on the casing To connect the KNX cable a standard bus connector is plugged...

Страница 5: ...ting instructions PowerBlock io64 Order number 77024 180 03 BMA 77024 io64_Rev1_en 5 7 ANNEX 1 Manual Control The outputs of the actuator have 2 push buttons and 2 status LEDs for each output channel...

Страница 6: ...annels of the actuator as configured in the ETS The Action simulates a telegram received at the switching object of the selected channel Binary Shutter Blind Press action Sends Toggle ON OFF command 0...

Страница 7: ...least 500ms If Blind channel is configured Press the two buttons of any channel at the same time for at least 500ms To change back to the normal Parameter Mode the same procedure should be repeated Be...

Отзывы: