Operating and mounting instructions 

 

PowerBlock io64                                                                      Order number: 77024-180-03  

 

BMA 77024-io64_Rev1_en 

7/7 

 

The Test Mode allows you to test all the loads/wiring connected to the channels. It is independent from the ETS 
configuration of the actuator (since the “Manual Control / Param mode + Test mode” is a default option, you can use 
the Test mode even before programming the actuator). 
 
Important note: Should a blind/shutter be connected to a channel, the 2 channels may never be closed at the same 
time. Therefore, even in Test mode, if the channel is configured as a blind, this safety measure is implemented. For this 
reason, it is better to first commission the OUTPUT: CHANNEL TYPE SELECTION before using the Test mode. 
 
To change into the test mode, any button can be used depending of the channel configuration: 
 
 - If “Binary” channel is configured: Press any button for at least 500ms  
 - If “Blind” channel is configured: Press the two buttons of any channel at the same time for at least 500ms 
 
To change back to the normal “Parameter Mode” the same procedure should be repeated. Be aware by changing back 
to “Parameter Mode” the device will restart. Also after the device has restarted and if the channel is configured to be a 
blind channel, it will do a calibration movement on the first movement command.  
 

 In order to indicate that the actuator is in Manual Control / Test Mode, the LED of the selected channel is 

continuously making a short blinking action every second; no matter whether the channel is ON (LED ON) or OFF (LED 
OFF). 
 
 
The Action switches/moves the channel, as you can see in the table below: 
 

Binary 

Shutter/Blind 

Press action: Sends toggle ON/OFF command to the 
relay (ON = Contact closed / OFF = Contact open) 
 

 LED = ON  (indicates channel status) 

 LED = OFF  (indicates channel status) 

Rising edge press action (Channel X): Contact closed 
Falling edge press action (Channel X): Contact open 
 

 LED = ON  (indicates channel status) 

 LED = OFF  (indicates channel status) 

 

Содержание Power Block Series

Страница 1: ...packaging Application programs The following application programs are currently available for the PowerBlock device 77014 PowerBlock io64 11 0110 Installation device Risk of death by electric shock T...

Страница 2: ...m 0 5 Nm Number of inputs Total inputs 6 binary analog mixed inputs with 2 common terminals Art der Eing nge Binary Analog Ready for Dry contacts Standard movement detector with dry contact output Sen...

Страница 3: ...boxes on 35 mm DIN rails and wall boxes 5 4 6 2 6 1 2 1 3 8 72mm 4 DIN RAIL 7 1 7 2 1 KNX bus connector 2 Programming button 3 Programming LED 4 SD card slot only for internal use 5 Outputs connector...

Страница 4: ...e are labelled clearly The power supply is connected to the bottom right hand side connector according to the order indicated on the casing To connect the KNX cable a standard bus connector is plugged...

Страница 5: ...ting instructions PowerBlock io64 Order number 77024 180 03 BMA 77024 io64_Rev1_en 5 7 ANNEX 1 Manual Control The outputs of the actuator have 2 push buttons and 2 status LEDs for each output channel...

Страница 6: ...annels of the actuator as configured in the ETS The Action simulates a telegram received at the switching object of the selected channel Binary Shutter Blind Press action Sends Toggle ON OFF command 0...

Страница 7: ...least 500ms If Blind channel is configured Press the two buttons of any channel at the same time for at least 500ms To change back to the normal Parameter Mode the same procedure should be repeated Be...

Отзывы: