IOT-WORKSHOP
DTU-H10X
Wi-Fi/Ethernet to RS485/RS232 Server User Manual
http://www.iotworkshop.com
- 62 -
AT+ FVER=<n/z><CR>
+ok<CR><LF><CR><LF>
Parameters:
status: device working mode..
n: router mode.(default mode)
z: bridge mode.
5.2.2.54.
AT+WMAC
Function: Set/Query device MAC address;
Format:
Query Operation
AT+ WMAC<CR>
+ok=<address><CR><LF><CR><LF>
Set Operation
AT+ WMAC=<address><CR>
+ok<CR><LF><CR><LF>
Parameters:
address: device MAC address in AP mode.
The device
‟s STA MAC address is AP‟s MAC address plus 1. For example, AP address:
ACCF23208888, then STA address: ACCF23208889.
5.2.2.55.
AT+PING
Function: PING command;
Format:
Set Operation
AT+ PING=<address><CR>
+ok=<status><CR><LF><CR><LF>
Parameters:
address: target IP address.
Status:command result.
5.2.2.56.
AT+HTPSV/AT+HTTPURL
Function: Query/Set device http address and port, it is valid only in httpdclient mode,
setting is valid after reboot
Format:
Query Operation
AT+HTPSV/AT+HTTPURL<CR>
+ok=<IP,Port><CR>< LF ><CR>< LF >
Set Operation
AT+HTPSV/AT+HTTPURL=<IP,Port><CR>
+ok<CR>< LF ><CR>< LF >
Parameters:
IP: HTTP server address or domain name, default is 10.10.100.200
Port: HTTP server port, default is 80.