IOT-WORKSHOP
DTU-H10X
Wi-Fi/Ethernet to RS485/RS232 Server User Manual
http://www.iotworkshop.com
20
10.10.100.100
)
.So for above networking, PC1(left laptop) at internal subnet can initiate a
connection to PC2
, but PC2 can‟t active initiate a connection to PC1, they are in a different
subnetwork.
2.2.3.
Ethernet Interface Networking (As STA, Z-Ver)
Laptop
Wireless
RJ45 Ethernet
IP:192.168.1.101
Laptop
IP:192.168.1.1
Wireless
IP:192.168.1.102
STATIC IP:192.168.1.10
Figure 13.
Ethernet Interface Networking (As STA, Z-Ver)
For above networking, device works as STA and device configured as bridge mode(AT+FVER=z).
When device connect to AP, all devices connected to device Ethernet interface will get assigned
IP address from AP (For example: 192.168.1.101).For device works as bridge mode, it can be
treated as a transparent device and PC1, PC2 can communicate without any limit. But in this
networking, device needs assign a static LAN IP address (For example: 192.168.1.10) if device
also needs communication with AP or configuration through web page.