Wi-Fi/Ethernet to RS485/RS232 Server User Manual
http://www.iotworkshop.com
- 47 -
AT+ UARTFL=<len ><CR>
+ok<CR>< LF ><CR>< LF >
Parameters:
len: Range 64 ~4096; Unit: byte. Auto-frame trigger length;
5.2.2.8.
AT+ MODBEN
Function: Set/Query Modbus function, valid when reboot
Format:
Query Operation
AT+ MODBEN<CR>
+ok=<status><CR>< LF ><CR>< LF >
Set Operation
AT+ MODBEN=<status ><CR>
+ok<CR>< LF ><CR>< LF >
Parameters:
status: on/off; enable/disable Modbus function.
5.2.2.9.
AT+TMODE
Function: Set/Query data transmition mode;
Format:
Query Operation
AT+TMODE<CR>
+ok=<tmode><CR>< LF ><CR>< LF >
Set Operation
AT+ TMODE=<tmode><CR>
+ok<CR>< LF ><CR>< LF >
Parameters:
tmode: Data transmition mode
Through: Transparent transmition
Agreement: Serial command mode
GPIO: GPIO mode(Reserved)
Httpdclient
:
HTTPD Client mode
After device boots up again, the setting will be effective.
5.2.2.10.
AT+WMODE
Function: Set/Query WIFI work mode;
Format:
Query Operation
AT+WMODE<CR>
+ok=<mode><CR>< LF ><CR>< LF >
Set Operation
AT+ WMODE=<mode><CR>
+ok<CR>< LF ><CR>< LF >
Parameters: