A marker plot doesn’t start at the correct point on the paper
Cause:
The origin is not set.
Solution:
Position the pen where the plot
should start. Press the
Set Origin
key.
The printer does not complete the marker.
Cause:
1. Outdated software.
2. The
frame/panel size is mis-
matched between the printer
and the design software.
Solution:
1. Visit the Ioline Web site to
download upgrades. Or, contact
Ioline Customer Service.
2. Check the panel size in the
software. It should be equal to or
lower than the printer panel size.
Send plot files from FlexPlot.
When a marker plot file is sent, nothing happens.
Cause:
A communication problem has oc-
curred or the printer is in
STOP
(red light) mode.
Solution:
Make certain the communication port
is connected and configured properly.
Position the marker on the carriage
where the plot should start and press
the
Set Origin
key to put the printer
in
START
(green light) mode.
No power when printer is turned on; keypad lights stay dark.
Cause:
1. The
power cord is damaged or
disconnected.
2. The printer is damaged and
needs professional service.
Solution:
1. Check the power connection.
2. Contact an Ioline distributor or
Ioline Customer Service.
Poor line quality.
Cause:
1. Ink cartridge is improperly
installed.
2. Frame Gap setting is incorrect.
3. Carriage electronics or cables
are damaged.
4. Ink cartridge is empty.
Solution:
1. Remove and reinstall ink car-
tridge.
2. Use the
Control Center
to
adjust frame gap as shown in
the
Routine Maintenance
chapter.
3. Contact Ioline customer service.
4. Install a new ink cartridge.
Common Issues
Содержание FlexJet E
Страница 1: ...User Guide Ioline FlexJet E StudioJet Printers ...
Страница 3: ...User Guide Ioline FlexJet E Printers ...
Страница 7: ...NOTES ...
Страница 8: ...NOTES ...
Страница 20: ...22 Ioline FlexJet E User Guide This page intentionally left blank ...
Страница 56: ...58 Ioline FlexJet E User Guide This page intentionally left blank ...
Страница 64: ...66 Ioline FlexJet E User Guide This page intentionally left blank ...