Goodrive300-LIFT series inverter
Function parameters
-35-
the password can be canceled. If
is not 0 during powering on, then the parameter is protected
by the password. When modify parameters by serial communication, the password function also
follows the above rules.
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P00 Group Basic function group
P00.00
Speed control
mode
0: Sensorless vector control (SVC) mode 0
1: SVC mode 1
2: V/F control
3: Closed-loop vector control
2
◎
P00.01 Run command
channel
0: Keypad ("LOCAL/REMOT" off)
1: Terminal ("LOCAL/REMOT" blinking)
2: Communication ("LOCAL/REMOT" on)
3: CAN ("LOCAL/REMOT" on)
1
◎
P00.02 Lift rated speed 0.100
–
4.000m/s
1.500m/
s
◎
P00.03 Speed command
selection
0: Keypad
1: AI1
2: AI2
3: Multi-step speed running
4: Remote communication
5: AI1 tracking running
6: CAN communication-based setting
7: CAN communication-based reference
3
◎
P00.04
Max. output
frequency
10.00
–
600.00Hz
50.00
Hz
◎
P00.05
Keypad set
speed
0
(lift rated speed)
1.500m/
s
○
P00.06
Running
direction
0: Default direction
1: Reverse direction
2: Forbid to run in reverse direction
0
◎
P00.07
Carrier
frequency mode
0: Fixed carrier frequency, set by
1: Auto adjustment
0
◎