Goodrive300-LIFT series inverter
Function parameters
-45-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
speed of the motor and its function code is
; p is the pole pair of the motor. 100.0%
corresponds to the rated slip frequency
△
f.
Setting range: 0.0
–
200.0%
P04.03
Motor vibration
control factor at
low frequency
0
–
100
10
○
P04.04
Motor vibration
control factor at
high frequency
0
–
100
10
○
P04.05 Motor vibration
control threshold
In SVPWM control mode, current fluctuation
may occur to the motor at some frequency,
especially the motor with big power. The motor
cannot run stably or overcurrent may occur.
These phenomena can be canceled by adjusting
this parameter.
Setting range of
: 0
–
100
Setting range of
: 0
–
100
Setting range of
: 0.00Hz
(max.
output frequency)
30.00
Hz
○
P04.06
Energy-saving
operation
0: No operation
1: Automatic energy-saving operation (reserved)
0
◎
P04.07
Gain in SM
MTPA control 0~3000
50
○
P04.08
Integral in SM
MTPA control 0~3000
30
○
P05 Group Input terminals
P05.00
HDI input
selection
0: High-speed pulse input. See
1: Digital input. See
0
◎
P05.01
S1 function
selection
0: No function
1: Running up (FWD)
2: Running down (REV)
3: Running in inspection mode (EXM)
4: Emergency running (EMER)
5: Coast to stop (FSTP)
1
◎
P05.02
S2 function
selection
2
◎