Goodrive300-LIFT series inverter
Function parameters
-50-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P06.13
AO1 output
upper limit
analog output. When the output value exceeds
the range of set maximum or minimum output, it
will count according to the low-limit or upper-limit
output.
When the analog output is current output, 1mA
equals to 0.5V.
In different cases, the corresponding analog
output of 100% of the output value is different.
See each application for detailed information.
10V (20mA)
0.0%
100.0%
AO
Setting range of
: -300.0%
Setting range of
: -0.00V
–
10.00V
Setting range of
300.0%
Setting range of
: -0.00V
–
10.00V
Setting range of
: -0.000s
–
10.000s
Setting range of
: -300.0%
Setting range of
: -0.00
–
50.00kHz
Setting range of
300.0%
Setting range of
: -0.00
–
50.00kHz
Setting range of
: -0.000s
–
10.000s
100.0%
○
P06.14
AO1 output of
upper limit
10.00V
○
P06.15 AO1 output filter
time
0.000s
○
P06.16
HDO output
lower limit
0.00%
○
P06.17
HDO output of
lower limit
0.0kHz
○
P06.18
HDO output
upper limit
100.0%
○
P06.19
HDO output of
upper limit
50.00kH
z
○
P06.20 HDO output filter
time
0.000s
○
P06.21
Reserved
0
–
65535
0
○
P06.22
Reserved
0
–
65535
0
○
P07 Group Human-machine interface
P07.00 User's password 0
–
65535
0
○
P07.01 Parameter copy
Ones place:
0: No operation
1: Upload function parameters to the keypad
from machine
2: Download function parameters (including
motor parameters) from the keypad to machine.
3: Download function parameters (excluding the
motor parameters of
) from the keypad to
machine.
4: Download function parameters (including only
motor parameters of
) from the keypad to
0×100
◎