background image

www.InvisibleFence.com

 

4

 

 

 

Table of Contents

 

Important  Precautions  ................................................................................................................. 2-3

 

Components .............................................................................................................................. 5

 

How the System Works ............................................................................................................. 5

 

Operating Guide ................................................................................................................... 6

 

Charging ..................................................................................................................... 6

 

Turning On and Off ..................................................................................................... 6 

Control Panel .................................................................................................................. 7

 

Shields

®

 Operation ........................................................................................................ 7-8

 

Adjust Signal Field Range

 ................................................................................... 7 

Verify Signal Field Range

 .................................................................................... 8 

Changing the Channel Setting

 ................................................................................. 8 

Boundary Plus

®

 Operation ................................................................................................. 8-9 

Adjust Signal Field Range

 ................................................................................... 8 

Verify Signal Field Range

 .................................................................................... 9 

Multi-Area Avoidance ................................................................................................. 9

 

Programming the Computer Collar

®

 Unit .

……………………………………………………… …10 

Training Guide ......................................................................................................................... 11

 

For Pets trained to the Invisible Fence® Brand Outdoor Pet

 

Containment System ................................................................................................ 10

 

For Pets New to Invisible Fence® Brand ...................................................................... 10

 

Troubleshooting  .............................................................................................................................. 11

 

Battery Disposal  ................................................................................................................................. 12

 

Perchlorate  Battery ............................................................................................................................ 13

 

Important   Recycling   Advice  .......................................................................................................... 13

 

Compliance  ....................................................................................................................................... 14

 

Содержание Invisible Gate Plus

Страница 1: ...Invisible Gate Plus Owner s Manual Please read this entire guide before operating www InvisibleFence com ...

Страница 2: ...afety alert symbol indicates a hazardous situation which if not avoided could result in minor or moderate injury CAUTION used without the safety alert symbol indicates a hazardous situation which if not avoided could result in harm to your pet NOTICE is used to address safe use practices not related to personal injury Not every pet can be trained to avoid the established boundary Sometimes even a ...

Страница 3: ...ustments to your pet avoidance containment system All Invisible Fence Brand pet containment systems are designed for domesticated animal use only Never attempt to use this product for any purpose not specifically described in this manual Congratulations on your purchase of the Invisible Gate Plus solution Please read and review this entire manual to become familiar with Invisible Gate Plus solutio...

Страница 4: ...Field Range 8 Changing the Channel Setting 8 Boundary Plus Operation 8 9 Adjust Signal Field Range 8 Verify Signal Field Range 9 Multi Area Avoidance 9 Programming the Computer Collar Unit 10 Training Guide 11 For Pets trained to the Invisible Fence Brand Outdoor Pet Containment System 10 For Pets New to Invisible Fence Brand 10 Troubleshooting 11 Battery Disposal 12 Perchlorate Battery 13 Importa...

Страница 5: ...rgeable battery pack You may use the included AC adapter for locations near an electrical outlet The AC adapter is also used for charging the transmitter The Transmitter has four control buttons Three under the bottom cover next to the display o Two for controlling the signal field range o One for use when programming the Computer Collar unit to the Invisible Gate Plus transmitter One on the top s...

Страница 6: ...er button will illuminate red while charging o The power button will illuminate green when charging is complete Battery life of approximately 30 days can be expected from a fully charged battery The Invisible Gate Plus transmitter will give an audible chirp once every 30 seconds and the power button will flash red every 5 seconds when the battery is low and charging is required Turning ON and OFF ...

Страница 7: ... separate pet when unit is set to Shields mode This switch is unused in Boundary Plus mode Refer to Different Rules for Different Pets technology section Range and Program Buttons o Buttons Used to adjust the signal field range o P Button Used to program a Computer Collar unit to Channel A or B when setting Different Rules for Different Pets technology Shields Operation In Shields mode your pet s ...

Страница 8: ...just and verify signal field range o Replace the control panel cover and hand tighten the four screws Note Ensure the O ring is seated in the channel before replacing the control panel cover Failure to do so may allow moisture leakage and possible failure of the device Boundary Plus Operation In Boundary Plus mode your pet s Computer Collar unit will activate as your pet crosses over the Invisible...

Страница 9: ... more pets this setting is usually sufficient as long as all pets are required to avoid the same protected areas like keeping all pets away from the dining room off the sofa etc In some multi pet homes it may be desired to allow one pet access to an area while denying the same access to another pet When set to Channel A Code A the Invisible Gate Plus transmitter denies access to pets wearing a Com...

Страница 10: ...is set to A B Press and hold the PROGRAM button while lowering the Computer Collar unit from directly above the Invisible Gate Plustransmitter Stop lowering when the Computer Collar unit begins to flicker yellow and release the PROGRAM button on the transmitter when the Computer Collar unit begins to flash green The Computer Collar unit is now programmed to the desired channel Verify operation by ...

Страница 11: ... Collar units as instructed on Page 9 2 Remove the pets from the designated area and set up the Invisible Fence Brand training flags as above 3 Add the new visually enhanced elements The easiest cue would be to use blue painters tape Use 4 6 strips of painters tape between the flags on the floor Painters tape can easily be removed without causing damage to different types of surfaces 4 Bring in th...

Страница 12: ...If your pet has a strong reaction to get away from the designated area after hearing the tone contact your Dealer right away Your Invisible Fence Brand dealer will be able to help customize training and the appropriate training settings for your pet If you choose to train yourself here are the steps to follow 1 Use the Invisible Fence Brand training flags to mark the desired area Flags should be s...

Страница 13: ...eat and turn completely black The LCD will return to normal when the temperature drops below 150ºF 65ºC Operating the transmitter when the LCD is black will not damage the device Range is too low or too high Check for low battery audible chirp once every 30 seconds and flashing LCD If low battery is indicated plug the AC adapter into the unit and charge for 2 hours Adjust the Invisible Gate Plus t...

Страница 14: ... 1 rechargeable Lithium Ion Polymer Li ion battery pack with a 3 7 Volt 1900mAh 7 03Wh capacity PerchlorateBattery PerchlorateMaterial special handling may apply See www dtsc ca gov hazardouswaste perchlo rate Important Recycling Advice Please respect the Waste Electrical and Electronic Equipment regulations in your country This equipment must be recycled If you no longer require this equipment do...

Страница 15: ... and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a specific installation If interference does occur to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following...

Страница 16: ...ce com 15 Dealer Name Dealer Phone System Frequency Notes 800 578 3647 USA 865 777 5404 International 400 XXXX X 2015 Radio System Corporation All rights reserved Protected by Patents U S 7 046 152 7 068 174 7 204 204 ...

Отзывы: