background image

2181383H -

 July 2021

IMPORTANT SAFETY ADVICE

The shower head and hose supplied with 
this product are a safety critical part of your 
shower. Failure to use genuine Triton parts may 
cause injury and invalidate your guarantee.

FOR YOUR SERVICE REFERENCE

NOTE DOWN THE PRODUCT CODE BELOW

(FROM THE LABEL ON THE FRONT OR TOP OF THE BOX)

ALTERNATIVELY REGISTER BY TEL: 024 7637 8321

INSTALLATION AND OPERATING INSTRUCTIONS 

Please read this book thoroughly and familiarise yourself with all instructions before commencing 
installation and keep it for future reference. 

The mixer shower installation 

MUST

 be carried out by a suitably qualified person, 

in the sequence 

of this instruction book. 

EDEN

Thermostatic
Bar Diver ter

REGISTER ONLINE

ENTER A PRIZE DRAW

WIN

£100

LOVE2SHOP VOUCHERS

VISIT OUR WEBSITE TODAY

TRITONSHOWERS.CO.UK/REGISTER

PRODUCT REGISTRATION IS ONLY AVAILABLE

TO UNITS PURCHASED & INSTALLED IN THE UK

86005000

Summary of Contents for EDEN Bar Diverter

Page 1: ...EL 024 7637 8321 INSTALLATION AND OPERATING INSTRUCTIONS Please read this book thoroughly and familiarise yourself with all instructions before commencing installation and keep it for future reference The mixer shower installation MUST be carried out by a suitably qualified person in the sequence of this instruction book EDEN Thermostatic Bar Diverter REGISTER ONLINE ENTER A PRIZE DRAW WIN 100 LOV...

Page 2: ...ING THE MAXIMUM TEMPERATURE STOP SETTING 10 TEMPERATURE ADJUSTMENT RANGE 11 RECOMMENDED OUTLET TEMPERATURES 11 OPERATING THE SHOWER DIVERTER 12 TMV2 AND FLOW RATES 13 MAINTENANCE 14 FAULT FINDING 15 16 GUARANTEE SERVICE POLICY ETC rear cover To check the product suitability for commercial and multiple installations please contact Triton s specification advisory service before installation Please se...

Page 3: ...d riser rail pipe 4 Handset 5 Handset holder 6 Hose 7 Eden thermostatic mixer valve 8 Collar outlet assembly Arm mounting plate not shown DIMENSIONS MAIN COMPONENTS All dimensions listed in this fitting book regarding the product and installation are approximate 7 1 3 2 4 5 6 8 ...

Page 4: ...ts of scale in hard water areas Pressure Reducing Valve On sites where the running pressure is above 5 bar the use of a suitably sized pressure reducing valve fitted in the cold mains supply pipework can provide nominally equal pressures at the mixer shower Water Minimum Flow Rate For best performance within the specified running pressure range a minimum flow of 8 litres per minute should be avail...

Page 5: ...e filters that may become blocked if debris is not flushed through before fitting Commercial Applications It is recommended that for all commercial applications easily accessible in line filters are used to aid maintenance Hard Water Areas a If it is intended to operate the shower in areas of hard water above 200 ppm temporary hardness a scale inhibitor may have to be fitted For advice on the scal...

Page 6: ...boost pressures as shown please refer to the pump installation guide to establish the minimum head requirements for automatic operation of the pump Hot water cylinder Mixer Cold supply Hot supply Alternative supply must be below vent pipe tee Cold water mains supply Drain valve Gate valve Stop valve Cold water cistern Minimum head Other draw offs Draw off must point down to avoid airlock issues Ri...

Page 7: ...For systems with no cold water take off after the appliance reducing valve it will be necessary to fit an additional drop tight pressure reducing valve when the mains pressure is over 5 bar The drop tight pressure reducing valve MUST be set at the same value as the unvented package pressure reducing valve NOTE An additional expansion vessel may be required if a second pressure reducing valve is in...

Page 8: ...bar running An expansion vessel MUST be fitted and regularly maintained to ensure the unit is not damaged by excess pressures This may already be installed externally or internally within the thermal store check with thermal store manufacturer Flow Return Boiler Blender valve Cold mains supply Hot water Stop tap Expansion vessel Pressure reducing valve Service valves Mixer Fig 6 Diagrammatic view ...

Page 9: ...efer to fig 7 for correct siting of the shower The mixer shower should be positioned as detailed with all controls within comfortable reach of the user The handset can be positioned on either side of the riser rail pipe The valve must be installed in a position that allows for easy access for future maintenance and commissioning PUSH FIT BRACKET If the product has been supplied with the push fit b...

Page 10: ...ed If the wall is brick plasterboard or a soft building block appropriate wall plugs and screws should be fitted Secure the arm mounting plate to the wall If the handset holder is required depress the button on the handset holder fig 10 slide the holder onto the pipe The threaded section of the riser pipe should be at the top Screw the fixed shower head arm to the top of the riser pipe NOTE If the...

Page 11: ... by tightening the locking screw LEAK TESTING IMPORTANT Flush out the pipework in accordance with Water Regulations and Bylaws Fit the hose to the outlet without the shower head fitted and direct it towards the waste outlet Open the water isolating valves to the shower and check for leaks If any leaks are found rectify them before carrying out the commissioning procedure Fitting the Fixed Shower H...

Page 12: ...he diverter control 6 o clock position Fit the handles as shown in figs 14 15a 15b IMPORTANT DO NOT over tighten fitting screws Fit the temperature control making sure the maximum temperature stop pin is as close to the flat edge of the temperature stop as possible figs 14 15a Secure the temperature control in place with the retaining screw and fit the screw cap DO NOT over tighten Fit the diverte...

Page 13: ...showers 41 C for washbasins 38 C for bidets The mixed water temperatures must never exceed 46 C at terminal fitting The British Burns Association recommends 37 C to 37 5 C as a comfortable bathing temperature for children In premises covered by the Care Standards Act 2000 the maximum mixed water outlet temperature is 43 C ADJUSTING THE MAXIMUM TEMPERATURE STOP SETTING The maximum temperature stop ...

Page 14: ...ter control lever back towards the OFF setting fig 17 To use the handset turn the diverter control anti clockwise To decrease the flow turn the diverter control lever back towards the OFF setting To stop the water flow reposition the diverter control lever to the 6 o clock OFF position To adjust the water temperature rotate the temperature control right hand side clockwise for a cooler shower or a...

Page 15: ...equired If there is a residual flow during the commissioning or the annual check this is acceptable providing the temperature of the water seeping from the valve is no more than 2 C above the designated maximum mixed water outlet temperature setting of the valve NOTE Temperature readings should be taken at the normal flow rate after allowing for the system to stabilise The sensing part of the ther...

Page 16: ...ine maintenance of the internal of the valve will depend mainly on the water supply condition Experience of local conditions will dictate the intervals for inspection and in service testing guidance has been given below which can be adjusted for local requirements a Initially check the filters for debris once every three months and clean if necessary b Perform a thermal shut off test every three m...

Page 17: ...upplies from the heating system 2 5 Hot water supply blocked or restricted 1 1 1 Refer to the Commissioning section 1 2 1 Reposition temperature control knob 1 3 1 Reposition temperature control knob 1 4 1 Turn off the shower and consult a competent plumber or contact Customer Experience 1 5 1 Reduce the simultaneous demand from the supply 2 1 1 Refer to the Commissioning section 2 2 1 Reposition ...

Page 18: ...ct the inlet filters Clean if necessary 3 3 1 Turn off the shower and consult a suitably competent plumber 3 4 1 Clean shower head 3 5 1 Reduce the simultaneous demand 3 5 2 Make sure stop service valves are fully open 3 5 3 Check if sufficient water pressure 4 1 1 Fit a pressure reducing valve 5 1 1 Fit a pressure reducing valve 6 1 1 Renew flow control cartridge 3 Water does not flow or shower p...

Page 19: ...Thermostatic bar mixer shower 17 ...

Page 20: ...ment of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verify your requirements using the Information contained in the user guide Triton cannot accept liability for incorrect part identification TRITON UK STANDARD GUARANTEE This guarantee applies only to products installed within the United Kingdom and d...

Reviews: