Optidrive E2 Single Phase Output User Guide V3.10
www.invertekdrives.com
14
Pow
e
r W
iri
n
g
4
4.7.
Connection Diagram – IP20 Open & IP66 (Nema 4X) Non Switched Units
M
1
2
3
4
5
6
7
8
9
V
Earth
PE
V
U
{
F
G
H
I
L1/L
L2/N
E
D
C
B
A
11
10
Power Connections
A
Incoming Power Supply
B
Isolator / Disconnect
C
MCB or Fuse
D
Optional Input Choke
E
Optional Input Filter
F
Optional Brake Resistor
G
Shielded Motor Cable
H
Analog Output
I
Relay Output
Control Connections
1
+ 24 Volt (100mA) User Output
2
Digital Input 1
Default: Drive Run / Stop
3
Digital Input 2
Default: No Function
4
Digital Input 3
Default: Analog / Preset Speed
5
+ 10 Volt Output
6
Analog Input 1:
Default: 0 – 10 Volt
7
0 Volt
8
Analog Output
Default: 0 – 10 Volts
9
0 Volt
10
Relay Output
Default: Drive Healthy (Closed)
11
4.8.
Connection Diagram – IP66 (Nema 4X) Switched Units
1
2
3
4
5
6
7
8
9
Earth
PE
V
U
M
V
F
G
H
I
L1/L
L2/N
{
D
C
B
A
E
J
K
Power Connections
A
Incoming Power Supply
B
External MCB or Fuse
C
Optional Input Choke
D
Optional Input Filter
E
Internal Isolator / Disconnect
F
Optional Brake Resistor
G
Shielded Motor Cable
H
Analog Output
I
Relay Output
Control Connections
J
Internal Forward / Off Switch
(Reverse prohibited)
K
Internal Speed Control Pot
8
Analog Output
0 – 10 Volts
9
0 Volt
10
Relay Output
‘Drive Healthy’ = Closed
11