22
Procedure:
1). Connect the charge hose to the
charging cylinder, open the 2-way valve
and the 3-way valve.
Connect the charge hose which you
disconnected from the vacuum pump to
the valve at the bottom of the cylinder.
Make the cylinder bottom up to ensure the
liquid charge.
2). Purge the air from the charge hose.
Open the valve at the bottom of the
cylinder and press the check valve on the
charge set to purge the air (be careful of
the liquid refrigerant).
3) Put the charging cylinder onto the
electronic scale and record the weight.
4) Operate the air conditioner at the
cooling mode.
5) Open the valves (Low side) on the
charge set and charge the system with
liquid refrigerant.
6).When the electronic scale displays the
proper weight (refer to the table),
disconnect the charge hose from the 3-way
valve’s service port immediately and turn
off the air conditioner before disconnecting
the hose.
7). Mount the valve stem caps and the
service port
Use torque wrench to tighten the service
port cap to a torque of 18N.m.
Be sure to check for gas leakage.
6.5 Adding the refrigerant after running
the system for many years
Procedure:
1). Connect the charge hose to the 3-way
service port, open the 2-way valve and the
3-way valve.
Connect the charge hose to the valve at
the bottom of the cylinder. Make the
cylinder bottom up to ensure liquid charge.
2). Purge the air from the charge hose.
Open the valve at the bottom of the
cylinder and press the check valve on the
charge set to purge the air (be careful of
the liquid refrigerant).
3) Put the charging cylinder onto the
electronic scale and record the weight.
4) Operate the air conditioner at the
cooling mode.
5) Open the valves (Low side) on the
charge set and charge the system with
liquid refrigerant.
6).When the electronic scale displays the
proper weight (refer to the gauge and the
pressure of the low side), disconnect the
charge hose from the 3-way valve’s service
port immediately and turn off the air
conditioner before disconnecting the hose.
7). Mount the valve stem caps and the
service port
Use torque wrench to tighten the service
port cap to a torque of 18N.m.
Be sure to check for gas leakage.
6.6 Re-installation while the indoor unit
need to be repaired
1. Collecting the refrigerant into the
outdoor unit
Содержание P8MVI32-09WiFi
Страница 2: ......
Страница 14: ...12 For P8MVI32 09WiFi For P8MVI32 09WiFi P8MVO32 09 P8MVI32 12WiFi P8MVO32 12...
Страница 15: ...13 For P8MVI32 18WiFi P8MVO32 18 For P8MVI32 24WiFi P8MVO32 24...
Страница 19: ...17 For P8MVO32 24...
Страница 34: ...32 8 Wiring Diagram 8 1 Indoor Unit P8MVI32 09WiFi P8MVI32 12WiFi P8MVI32 18WiFi P8MVI32 24WiFi...
Страница 35: ...33 8 2 Outdoor Unit P8MVO32 09 P8MVO32 12 P8MVO32 18 P8MVO32 24...
Страница 70: ...68...
Страница 71: ......
Страница 72: ...Scan here to download the latest version of this manual WALL MOUNTED UNIT AIR CONDITIONING SYSTEMS...