46
Note: The network address are the Dip-switch F1 address plus Rotary switch ENC3
address.
10.5.4.2 If it receives the network address set by remote controller, the network address
will be changed .If it receives the cancel signal of network address set by remote
controller, the network address will be disposed according to the setting of Dip-switch F1
and
Rotary switch
ENC3.
10.5.4.3 The network address is useless for 4-cored wired controller, only valid for Central
controller and Non-polar wired controller.
10.5.5. Non-polar wired controller
10.5.1 Each Non-polar wired controller can be connect to Max. 16 indoor units .All the
indoor units must be the same series, and in the same network. The address of
Multi-function board must be set differently. The connection method must be Bus type.
10.5.2 The setting state are the same for all the indoor units connected to the same
Non-polar wired controller
10.5.6.Alarm port output
10.5.6.1 When the Air-condition in off state, the output signal is closed.
10.5.6.2 When the Air-condition in malfunction state, the output signal is closed.
10.5.6.3 When the Air-condition in on state, the output signal is disconnected.
10.5.7
.
Wiring diagram
10.5.7.1 Connected to 4-cored wired controller or Central controller
Note: It must use shield cables to connect with 4-cored wired controller and Central
controller.
The length should not exceed 50m.
Содержание P8MVI32-09WiFi
Страница 2: ......
Страница 14: ...12 For P8MVI32 09WiFi For P8MVI32 09WiFi P8MVO32 09 P8MVI32 12WiFi P8MVO32 12...
Страница 15: ...13 For P8MVI32 18WiFi P8MVO32 18 For P8MVI32 24WiFi P8MVO32 24...
Страница 19: ...17 For P8MVO32 24...
Страница 34: ...32 8 Wiring Diagram 8 1 Indoor Unit P8MVI32 09WiFi P8MVI32 12WiFi P8MVI32 18WiFi P8MVI32 24WiFi...
Страница 35: ...33 8 2 Outdoor Unit P8MVO32 09 P8MVO32 12 P8MVO32 18 P8MVO32 24...
Страница 70: ...68...
Страница 71: ......
Страница 72: ...Scan here to download the latest version of this manual WALL MOUNTED UNIT AIR CONDITIONING SYSTEMS...