![INVENTOR ICI-12 Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/inventor/ici-12/ici-12_owners-manual_2084043061.webp)
59
The air conditioner select from COOL, HEAT, DRY, FAN modes automatically.
* On operating, press the AUTO button, the air conditioner will stop.
Note:
The “TEST” button on the cover No.
Ⅱ
is specially for testing the air conditioner. When
pressing it ,the air conditioner will be forced to operate or stop. Do not press it when air
conditioner is in normal operation.
For the following items, take special care during construction and check after installation is finished.
Items to check
If not properly done, what is likely to happen
Check
Is the indoor unit fixed firmly?
The unit may drop, vibrate or make noise.
Is the gas leakage test finished?
It may result in insufficient cooling.
Is the unit fully insulated?
Condensate water may drip.
Does drainage flow smoothly?
Condensate water may drip.
Does the power supply voltage correspond to
that shown on the nameplate?
The unit may malfunction or the components burn out.
Are wiring and piping correct?
The unit may malfunction or the components burn out.
Is the unit safely grounded?
Risk of electric leakage.
Is wiring size according to specifications?
The unit may malfunction or the components burn out.
Is something blocking the air outlet or intake of
either the indoor or outdoor unit?
It may result in insufficient cooling.
Have records of refrigerant piping length and
additional refrigerant change been made?
Volume of refrigerant change in the system is not clear.
Note to the installer:
Be sure to instruct the customer how to operate the system and show him/her the attached operation
manual.
Be sure the electric supply that user applies is beyond the bounds of tolerances (+/-10%, +/-1Hz).
The ambient temperature should be at 5-40°C ,and the humidity be at 30-95% .
Transport/storage temperature should be at -25-55°C and for short period not exceeding 24h at up to
+70°C.
The installation altitude is beyond the hight of 1000m.
Содержание ICI-12
Страница 1: ...66129903850 ICI 18 ICI 24 ICI 36 ICI 45 ICI 50 Casette Unit ICI 12...
Страница 3: ...1 Names and functions of parts 1 ULS 12 ULS 18 ULS 24 ICI 18 ICI 24 ICI 12...
Страница 4: ...2 ULS 36 ICI 36 ULT 36 ICI 36 ULT 45 ICI 45 ULT 50 ICI 50...
Страница 22: ...TIMER operation procedure 20...
Страница 24: ...How to inser t batteries 22...
Страница 35: ...6 Optimum operation 33...
Страница 37: ...The following are not troubles 35...
Страница 38: ...8 Installation notes This should be done by professional 36...
Страница 39: ...9 Care and maintenance Please cut off the power supply after you used the air conditioner 37...
Страница 63: ......