Put the screw through the loop of the single wire and fix the loop at the terminal board.
2. Connection of multiple twisted wires
(
1
)
Use wire stripper to strip the insulation layer (10mm long) from the end of the multiple
twisted wires.
(
2
)
Remove the screw at the terminal board of the air-conditioning unit.
(
3
)
Use crimping pliers to connect a terminal (matching the size of the screw) at the end of the
multiple twisted wires.
(
4
)
Put the screw through the terminal of the multiple twisted wires and fix the terminal at the
terminal board.
Warning:
If the power supply flexible line or the signal line of the equipment is damaged, only use special
flexible line to replace it.
1
、
Before connecting lines, read the voltages of the relevant parts on the nameplate. Then carry out
line connection according to the schematic diagram.
2
、
The air-conditioning unit shall have special power supply line which shall be equipped with
electricity leakage switch and air switch, so as to deal with overload conditions.
3
、
The air-conditioning unit must have grounding to avoid hazard owing to insulation failure.
4
、
All fitting lines must use crimp terminals or single wire. If multiple twisted wires are connected
to terminal board, arc may arise.
5
、
All line connections must conform to the schematic diagram of lines. Wrong connection may
cause abnormal operation or damage of the air-conditioning unit.
6
、
Do not let any cable contact the refrigerant pipe, the compressor and moving parts such as fan.
7
、
Do not change the internal line connections inside the air-conditioning unit. The manufacturer
shall not be liable for any loss or abnormal operation arising from wrong line connections.
8
、
shall not be liable for any loss or abnormal operation arising from wrong line connections.
54
Connection Of the Power Cable
1. Air-conditioning unit with single-phase power supply
(
1
)
Remove the front-side panel of the outdoor unit.
(
2
)
Pass the cable though rubber ring.
Содержание ICI-12
Страница 1: ...66129903850 ICI 18 ICI 24 ICI 36 ICI 45 ICI 50 Casette Unit ICI 12...
Страница 3: ...1 Names and functions of parts 1 ULS 12 ULS 18 ULS 24 ICI 18 ICI 24 ICI 12...
Страница 4: ...2 ULS 36 ICI 36 ULT 36 ICI 36 ULT 45 ICI 45 ULT 50 ICI 50...
Страница 22: ...TIMER operation procedure 20...
Страница 24: ...How to inser t batteries 22...
Страница 35: ...6 Optimum operation 33...
Страница 37: ...The following are not troubles 35...
Страница 38: ...8 Installation notes This should be done by professional 36...
Страница 39: ...9 Care and maintenance Please cut off the power supply after you used the air conditioner 37...
Страница 63: ......