IV- SMART+ OHIO VENTILATION UNIT
iV-Smart
+
ventilation system
•
Installation instructions
7.2
Dimensions
Designation
Depth/
length [mm] Width [mm]
Height
[mm]
Ø [mm]
Wall thickness
> 180
–
–
–
Wall opening for wall sleeve
Wall thick
-
ness
1)
–
–
180
Wall sleeve R-D160x495 (745)
495 (745)
–
–
160
Ohio protective hood
110
230
247
–
Flair inner cover V-233x233
61
2)
233
233
–
1)
incl. render, insulation, masonry and inner structure
2)
opened
Sectional drawing
Figure 14: Sectional drawing iV-Smart
+
Ohio ventilation unit (plan view)
A Render
B Masonry
C Plaster
1 Inner cover base plate
2 Inner cover panel
3
Wall sleeve
4 inVENTron: Xenion reversible fan
embedded in guiding vanes
5 Thermal accumulator
6 Metal sleeve
7 Protective grille
8 Joint tape
260
233
247
15
61
110
≥