![inVENTer sMove Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/inventer/smove/smove_user-manual_2083852013.webp)
13
SPECIFICATIONS
iV-Smart
+
ventilation system
•
Installation instructions
iV-Smart
+
, manual control:
Product fiche iV-Smart
+
according to VO 1254/2014 EU, dated 2014-07-11
Pt.
Description
Data
a
Supplier's name
inVENTer GmbH
b
Supplier's model identifier
iV-Smart
+
iV-Smart
+
Corner
iV-Smart
+
Ohio
c
SEC class / Specific energy con
-
sumption [kWh/(m²a)]
cold
-82.062
average
A
-39.422
warm
-14.995
d
Typology
BVU
e
Type of drive installed
2
f
Type of heat recovery system
regenerative
e
Thermal efficiency of heat recovery ƞ
t
[%]
87
h
Maximum flow rate (supply air) [m³/h]
58
i
Electric power input [W]
6
j
Sound power level L
wa
[dB (A)]
44
k
Reference flow rate [m³/h]
42
l
Reference pressure difference [Pa]
0
m
Specific power input (SPI) [W/m³/h]
0.15
n
Control factor
1
o
Internal/external leakage rate [%]
n. a.
p
Mixing rate [%]
n. a.
q
Position of visual filter warning
Controller
r
Regulated supply and exhaust grilles in the facade
(one-direction devices only)
no
s
Internet:
www.inventer.eu
t
Airflow sensitivity [%]
29.4
u
Indoor and outdoor air tightness [m³/h]
6.3
v
Annual electricity consumption [kWh/(m²a)]
2.07
w
Annual heating saved [kWh/(m²a)]
cold
87.23
average
44.59
warm
20.16