![inVENTer sMove Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/inventer/smove/smove_user-manual_2083852018.webp)
18
IV- SMART+ VENTILATION UNIT
iV-Smart
+
ventilation system
•
Installation instructions
Exterior closure: Nova or Smart weather protection hood
Nova protective hood cover
Nova-R protective hood base plate
Figure 3:
Dimensioned drawing of Nova protective hood
Smart protective hood cover
Smart protective hood base plate
Figure 4:
Dimensioned drawing of Smart protective hood
A
A
279
A
─
A
23
88
313
21
252
221
148
7
4 x
Ø
4,8
Ø
168
1 Protective hood base plate
2 Exterior wall attachment with
Ø 8 mm, min. 50 mm deep (4 x)
3 Protective hood cover
4 Protective grid
5
Drip rail
44
222
56
285
4 x
Ø
5
180
90
180
1 Protective hood base plate
2 Exterior wall attachment with
Ø 8 mm, min. 50 mm deep (4 x)
3 Upper drip rail
4 Bottom drip rail
5 Fastening screws for cover (4 x)
6 Protective hood cover
1
2
3
4
3
1
5
1
1
2
5
4
3
6