background image

Y

Y

20

INSTALLATION AND ASSEMBLY

Ventilation device iV14-MaxAir 

 Installation and operating instructions

Using the Simplex wall installation system

Requirements:

The building project is in the shell construction phase.

 

Insert the Simplex wall installation system  

into the masonry at the appropriate point.

Observe 

the installation markings on/in the wall 

sleeve (red arrow): The integrated slope is directed 

towards the exterior wall to ensure that any 

condensate that may form can drain away.

 

Build the installation block into the masonry.

 

Apply insulation, plaster and render.

4.3 

Installing the fan BUS

Principle sketches for the cabling of the ventilation devices:

One after the other:

 

Shorten the wall sleeve on the exterior wall  

with a projection Y (

 4.4).

 

Install the fan BUS (

 4.3).

 

Continue with the installation of the weather 

protection hood (

 4.5). 

Star-shaped:

Switching power 

supply unit

Switching power 

supply unit

Control unit

Control unit

Terminal 

blocks

Ventilation devices

Ventilation 

devices

Operated in pairs

Operated in pairs

Operated in pairs

Operated in pairs

 

The Simplex wall installation system is installed.

Cable type LiYY, 3-wire, length see 

 Controller

Cable type LiYY, 3-wire, max 33 m

Содержание iV14-MaxAir

Страница 1: ...iV14 MaxAir Installation and operating instructions ...

Страница 2: ...ontent of this documentation has been checked for compliance with the described hardware and software Nevertheless deviations may still occur therefore no guarantee of compliance can be provided This documentation describes the functionality of the standard scope The documentation does not purport to cover all details on all types of the product and cannot cover every conceivable scenario for inst...

Страница 3: ...ice s exterior closure 24 4 6 Inserting the thermal accumulator insert 27 4 7 Connect the reversible fan to the controller and check its function 28 4 8 Starting ventilation unit 29 4 9 Installing the inner cover 30 5 Operation 32 5 1 Opening closing the inner cover 32 5 2 Tilting the inner cover 32 6 Cleaning and maintenance 33 6 1 Remove the inner cover panel 34 6 2 Cleaning replacing the dust f...

Страница 4: ...4 Ventilation device iV14 MaxAir Installation and operating instructions 11 Warranty and guarantee 49 12 Service 49 13 Annex 1 Connection log 50 14 Annex 1 Connection log 51 15 Annex 2 Cleaning log 52 ...

Страница 5: ...hazard Measures to avoid the hazard The signal word indicates the severity of the potential hazard unless the preventive measures are taken WARNING indicates possible danger of serious injury or death CAUTION indicates Direct danger of minor significant injury NOTE indicates Indicates a direct or possible risk of property damage due to an adverse event state If you see these signs ensure you obser...

Страница 6: ...portation proper storage and installation as well as careful operation and cleaning care Installation and assembly CAUTION The system may only be installed by qualified personnel Before starting work you should have a project plan showing the number of ventilation de vices the location of the ventilation devices the ventilation principle cross ventilation single room ventilation extract ventilatio...

Страница 7: ...ges NOTE The device has scratch sensitive plastic surfaces Do not touch the components with oily and or dirty hands Avoid contact with sharp or pointed objects e g rings Cabling connection of the reversible fan CAUTION The system s electrical connections may only be carried out by qualified electricians NOTE If the ventilation unit is operated with safety extra low voltage it has an operating volt...

Страница 8: ...l The equipment system may only be set up operated and cleaned in conjunction with this docu mentation and the documentation for the controllers Installation electrical connection and commissioning of the equipment system may only be performed by qualified personnel Qualified personnel within the meaning of the safety notices in this documentation are persons who are authorised to install put it i...

Страница 9: ...uiding vane elements and the Xenion EFP reversible fan The guiding vanes on both sides of the fan serve to straighten the air flow and ensure more efficient flow through the thermal accumulator The unique geometry of the Xenion EFP reversible fan effectively reduces sound transmission The standard length of the wall sleeve is 495 mm For thicker walls a wall sleeve with a length of 745 mm can be or...

Страница 10: ...ulator and inVENTron Flair inner cover Exterior closure Flex weather protection hood Wall sleeve 3 R D200 wall sleeve 4 Recess for fan BUS cable 5 Thermal accumulator with insulation 6 Thermal accumulator handle 7 Standard guiding vane R D200 8 Xenion EFP reversible fan 9 Slim guiding vane narrow 10 Guiding vane knob 11 BUS plug connection 12 Inner cover base plate 13 Dust filter 14 Inner cover pa...

Страница 11: ...tuations corresponds to class S2 according to DIN EN 13141 8 max 20 air flow deviation at 20 Pa In order to ensure the full functioning of the ventilation device throughout the entire year a temperature sensor is integrated into the Xenion EFP reversible fan This measures the temperature of the air flow an the fan If the temperature at the fan falls below 5 C the reversible fan is automatically sw...

Страница 12: ...ures Clust Air technology multi zone control easy installation touch operation and a wide variety of possible uses The MZ Home controller consists of a programming unit and at least one optionally up to a maximum of four Clust Air module s Each Clust Air module can control up to two iV14 MaxAir ventilation devices per zone within the accommodation unit This allows the MZ Home controller to provide...

Страница 13: ...ce in places where direct contact with water spray is possible Observe the specifications of VDE 0100 when choosing the installation location Observe the following minimum distances of the wall opening for the ventilation device 1 between two ventilation devices pair of devices operating in push pull mode in a room to prevent an airflow short circuit A B C 1 2 m 1 0 m 1 0 m 1 4 m y 1 2 m 0 75 y 1 ...

Страница 14: ...TALLATION Ventilation device iV14 MaxAir Installation and operating instructions 3 2 Position of the wall opening Figure 2 Dimensioned drawing of the iV14 MaxAir wall opening interior view 1 Minimum distance to adjacent components on the interior wall 3 Attach the weather protection hood at lintel height 2 Ensure a minimum distance to adjoining building components 4 Note insulation thickness and a...

Страница 15: ... R D200 wall sleeve 4 Exterior closure Weather protection hood 5 End stop tape 6 Thermal accumulator 7 inVENTron Xenion EFP reversible fan embedded in double guiding vane A Plaster interior structure B Masonry C Insulation D Render 3 4 Dimensions Designation Depth length mm Width mm Height mm Wall opening for wall sleeve Wall thickness1 Ø225 R D200x495 wall sleeve 745 495 745 Ø200 Flex weather pro...

Страница 16: ...tion hood base plate Figure 4 Dimensional drawing of Flex weather protection hood 1 Wall sleeve base plate 2 Fixing borehole exterior wall Ø 8 mm min 50 mm deep 4 x 3 Weather protection hood cover 4 Protective grid 5 Drip rail 1 Minimum distance to adjacent components on the interior wall 3 Attach the weather protection hood at lintel height 2 Ensure a minimum distance to adjoining building compon...

Страница 17: ...vice iV14 MaxAir Installation and operating instructions 1 Inner cover panel 2 SDE sound insulation insert 3 Holding plate 4 Inner cover base plate 5 Spacer 4 x 6 Fixing borehole interior wall Ø 6 mm 40 mm deep 4 x Flair inner cover Figure 5 Dimensional drawing of Flair V 233x233 inner cover ...

Страница 18: ... Report missing items immediately Figure 6 Standard components of the iV14 MaxAir ventilation device 1 Exterior closure 1 a Flex weather protection hood 1 b Exterior wall fixing elements 1 c End stop tape 1 d Sealing tape 2 R D200 wall sleeve 2 a Protective discs 2 b Mounting wedge set 3 iV14 MaxAir thermal accumulator insert 3 a Insulated thermal accumulator 3 b R D200 guiding vane 3 c Xenion EFP...

Страница 19: ...her protection hood 450 mm from borehole centre Minimum distance to adjoining components on the interior wall 250 mm from borehole centre Minimum frontal distance 300 mm for cleaning and care work Do not install the wall opening near radiators In new buildings and buildings with wooden stud construction we recommend the use of the optional D200 wall installation block or the Simplex wall installat...

Страница 20: ... the installation block into the masonry Apply insulation plaster and render 4 3 Installing the fan BUS Principle sketches for the cabling of the ventilation devices One after the other Shorten the wall sleeve on the exterior wall with a projection Y 4 4 Install the fan BUS 4 3 Continue with the installation of the weather protection hood 4 5 Star shaped Switching power supply unit Switching power...

Страница 21: ... wall opening of the ventilation device Re plaster the plaster masonry slot Ensure that the cable end protrudes approximately 500 mm into the interior space NOTE The cable sheath provides no resistance when laid under plaster Short circuit and cable fire If necessary lay the cable in the conduit Ö The fan BUS is installed Mill the plaster masonry slot between the control unit and the wall opening ...

Страница 22: ...the protective discs from the wall sleeve Insert the wall sleeve into the wall opening so it is flush with the interior wall Note the thickness of the plaster Ensure that the cut out for the fan BUS is on the interior wall side and near the plaster masonry slot Guide the fan BUS through the cut out in the wall sleeve X Y D A B C 4 4 Installing the wall sleeve Measuring tape angle grinder spirit le...

Страница 23: ...al accumulator or a suitable material to prevent it from deforming Foam seal the gap between the wall sleeve and masonry all the way around with non pressing 2K polyurethane foam NOTE Interruption of the thermal insulation composite system Damage to the building structure During installation replace the wall structure as far as the wall sleeve Observe the necessary barrier levels Align the two lat...

Страница 24: ...e cut out in the end stop tape at the bottom in the centre of the wall sleeve Before installation carry out a biocidal pre treatment water repellent pre treatment of the surface around the weather protection hood consult your planner regarding this Remove the protective discs from the wall sleeve on the exterior wall side Attach the end stop tape 380 x 15 mm on the exterior wall side in the upper ...

Страница 25: ...nd makes installation easier Insert the rawl plugs into the boreholes Screw the weather protection hood base plate into the rawl plugs using 4 screws and washers TIP When attaching the base plate of the Flex weather protection hood to exterior walls with insulation or when using the wall installation block Simplex wall installation system use wallplugs for insulation for fixing purposes These are ...

Страница 26: ... in behind the base plate Seal the joint between the cover and the exterior wall at the sides and top with a permanently elastic exterior sealant NOTE If the joint between the base plate and façade is sealed incorrectly the cover cannot be fitted After fitting the cover seal the joints between the cover and façade using permanently elastic exterior sealant on both sides and at the top Ö The Flex w...

Страница 27: ...rmal accumulator insert NOTE Do not store stack the thermal accumulator insert outside the wall sleeve as doing so will damage the thermal accumulator s ceramic Insert the thermal accumulator immediately after removing it from the packaging Requirements The exterior closure is fitted Remove the protective disc from the wall sleeve From the interior slide the thermal accumulator towards the weather...

Страница 28: ...III in the left pole Green cable IV in the middle pole Brown cable V in the right pole Align the clamping screws on the connector and socket in the same direction Plug the connected socket into the green connector on the fan Ö Extract air mode is set Ö The reversible fan is connected to the controller Set ventilation operating mode DL on the connected controller see the controller s installation a...

Страница 29: ...n operating in pairs must be swapped over Start in extract air mode direction Start in supply air mode direction 1 Wires on the connector to the fan 2 Connector 3 Socket 4 Fan BUS to controller 5 Clamping screws on the socket 6 Clamping screws on the connector Socket cable coming from controller Connector on the fan cable Extract air start direction Supply air start direction Terminal block Descri...

Страница 30: ...thermal accumulator Set heat recovery operating mode WRG on the controller See the controller s installation and operating instructions Ö The fan is connected to the controller 4 9 Installing the inner cover Spirit level pen hex key rawl plug pliers Break out the four tabs on the inner cover base plate with pliers at the predetermined breaking points Requirements The thermal accumulator insert has...

Страница 31: ...nts of the wall sleeve Place the inner cover base plate on the interior wall so that it covers the fixing elements of the wall sleeve Make sure that the marking arrow red arrow on the inner cover base plate is pointing upwards Screw the inner cover base plate to the wall sleeve s fixing elements using a hex key Insert the dust filter into the inner cover base plate Ensure you push the filter ring ...

Страница 32: ...ice 5 2 Tilting the inner cover To reduce noise and direct the air flow the Flair inner cover panel can be tilted up or down The inner cover is closed on the tilted side and the air flow is directed in the open direction This causes the sound pressure level to decrease The air flow is reduced if the inner cover is only partially opened Requirements The inner cover is open Slide the inner cover pan...

Страница 33: ...ce s power supply and put on gloves Detergents NOTE Due to the scratch sensitive plastic surface of the inner cover damage may occur to the surface Do not use sand soda acid or chlorine based cleaning agents A commercially available detergent in warm water can be used for cleaning The following tools may be used for cleaning lint free soft cloth soft brush vacuum cleaner Cleaning recommendations T...

Страница 34: ...ng mat Yearly Wind protection insert Wash the wind protection insert with warm water and detergent Inner cover base plate Clean the surface of the base plate with a damp cloth Cleaning from the outside Yearly Exterior closure of the weather protection hood Clean the surface of the cover and the protective grid at the outlet opening with a damp cloth 6 1 Remove the inner cover panel To clean and ch...

Страница 35: ... inner cover has been removed 6 1 Pull the dust filter out of the inner cover base plate by the tab Ö The dust filter has been removed Insert the cleaned or a new dust filter into the base plate Ensure you push the filter ring firmly between the fixing projections and the inner edge of the base plate The tab on the filter ring faces the interior Replace the cover on the four spacers Make sure that...

Страница 36: ...Step 1 Remove the inVENTron insert from the wall sleeve by using the knob Step 2 Remove the thermal accumulator from the wall sleeve by the handle Loosen the BUS plug in connector NOTE In case of damage to the ceramic thermal accumulator The thermal accumulator will no longer function Do not throw the ceramic thermal accumulator Store the ceramic thermal accumulator in the standing position outsid...

Страница 37: ...guiding vane upwards 2 1 NOTE Incorrect cleaning of the thermal accumulator leads to damage to the insulation on the thermal accumulator Always clean the thermal accumulator under warm running water Never clean it in the dishwasher Clean the thermal accumulator under warm running water Let the thermal accumulator drip dry Wait until the thermal accumulator is completely dry Ö You have cleaned the ...

Страница 38: ... is completely dry Step 2 Clean the reversible fan carefully with a soft brush 1 2 2x 1x Ö You have cleaned the thermal accumulator Reassemble the plug connection Step 1 From the interior slide the thermal accu mulator towards the exterior closure until it stops Make sure that the handle is pointing towards the interior Step 2 Insert the inVENTron from the interior into the wall sleeve so that you...

Страница 39: ...the base plate Ensure you push the filter ring firmly between the fixing projections and the inner edge of the base plate The tab on the filter ring faces the interior Replace the cover on the four spacers Make sure that the inVENTer logo is located at the bottom right hand corner Press the detent lugs inwards on the spacers Slide the cover onto the spacers Ö All spacers noticeably snap in Ö You h...

Страница 40: ...vel dB A 22 51 Standard sound level difference dB 38 45 Thermal efficiency of heat recovery η w 0 88 Input voltage V DC 6 16 Power consumption W 1 5 Specific fan power input W m h 0 14 Protection class DIN EN 61140 III Type of protection DIN EN 60529 IP20 Standard filter filter class DIN EN 779 2012 G4 Sensitivity of the air flow at 20 Pa DIN EN 13141 8 S2 Electrical protection area in accordance ...

Страница 41: ...ith sensor technology sMove without sensor technology 41 SPECIFICATIONS Ventilation device iV14 MaxAir Installation and operating instructions 7 2 IV14 MaxAir energy label according to ErP Directive Regulation 1254 2014 On the energy label you will find the following information from the product data sheet Energy efficiency class SEC class Sound power level Lwa Maximum air flow supply air A A ...

Страница 42: ...ypology BVU e Type of drive installed 2 f Type of heat recovery system regenerative g Thermal efficiency of heat recovery 88 h Maximum flow rate m h 90 i Electric power input W 9 j Sound power level dB A 49 k Reference flow rate m h 52 l Reference pressure difference Pa 0 m SPI W m h 0 14 n Control factor 0 65 o Internal external leakage rate n a p Mixing rate n a q Position of visual filter warni...

Страница 43: ...stalled 2 f Type of heat recovery system regenerative g Thermal efficiency of heat recovery 88 h Maximum flow rate m h 90 i Electric power input W 9 j Sound power level dB A 49 k Reference flow rate m h 52 l Reference pressure difference Pa 0 m SPI W m h 0 14 n Control factor 1 o Internal external leakage rate n a p Mixing rate n a q Position of visual filter warning Controller r Regulatetd supply...

Страница 44: ...er protection hood grey RAL 9006 1508 0158 Flex weather protection hood north RAL 7011 1508 0159 Flex weather protection hood anthracite RAL 7016 1508 0160 Flex weather protection hood custom colour 1508 0161 Wall sleeve with protective discs and mounting wedges Wall sleeve R D200x495 1506 0070 Wall sleeve R D200x745 1506 0071 Thermal accumulator insert iV14 MaxAir thermal accumulator insert 1507 ...

Страница 45: ... 233x233 2 x 1004 0158 R D200 V 177x177 sound absorbing mat 1004 0170 Sound protector SPR R D200 1004 0153 Wind protection insert WSE R D200 1004 0149 Round cable LiYY O 3x0 75 33m 1004 0020 Assembly wedge set block with 16 wedges 3009 0012 R D196x30 protective disc for wall sleeve 3007 0088 Simplex 365 incl R D200 wall sleeve 1506 0090 Simplex 490 incl R D200 wall sleeve 1506 0091 D230 V 280x249x...

Страница 46: ...e 3006 0393 Base plate IB Flair V 233x233 2003 0223 Cover IB Flair V 233x233 2003 0221 Cover IB Flair V 233x233 SDE 2003 0222 Spacer base plate IB 25 mm white 3006 0151 Base plate WSH Nova R WSH Flex white RAL 9010 3006 0272 Base plate WSH Nova R WSH Flex grey RAL 7004 3006 274 Cover WSH Flex white RAL 9016 2004 0202 Cover WSH Flex grey RAL 9006 2004 0203 Cover WSH Flex north RAL 7011 2004 0204 Co...

Страница 47: ...not operating in paired mode Connect the first fan in extract air mode and the second fan in supply air mode The rotational speed of the fan is too low Increase the output level Thermal accumulator is soiled Clean the thermal accumulator Noises Foreign body in the fan Remove foreign body from the fan Clean the ventilation unit Fan blades soiled Clean fan blades Thermal accumulator is not correctly...

Страница 48: ... to arrange environmentally friendly recycling and disposal of your old system They will dispose of the product in compliance with the applicable national regulations Ensure that the product s packaging is sorted correctly for disposal The table below contains disposal recommendations Product Material Disposal Flex weather protection hood Powder coated stainless steel ASA Waste metal collection co...

Страница 49: ...on about the warranty is available at www inventer de garantie 12 Service Claims Check the delivery for completeness and transport damage upon receipt using the delivery note Report missing items immediately and at the latest within 14 days to your supplier distributor or factory representative Warranty and guarantee claims In the case of a warranty or guarantee claim contact your local distributo...

Страница 50: ...evice iV14 MaxAir Installation and operating instructions 13 Annex 1 Connection log Ventilation device Floor Room name and position Ventilation zone Starting direction Supply air Extract air 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ...

Страница 51: ... iV14 MaxAir Installation and operating instructions 14 Annex 1 Connection log Ventilation device Floor Room name and position Ventilation zone Starting direction Supply air Extract air 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 ...

Страница 52: ... care Cleaning recommendations page 45 Date Number of devices inspected Cleaning control measure1 Comment Name Signature Components A B C 1 Cleaning control measure Control K Cleaning R Change W Components Description Scope Measure A Inner cover Filter Inner cover Clean Filter Check clean or replace if necessary depending on filter type B Ceramic thermal accumulator Xenion EFP reversible fan doubl...

Страница 53: ...ignature Components A B C 1 Cleaning control measure Control K Cleaning R Change W Components Description Scope Measure A Inner cover Filter Inner cover Clean Filter Check clean or replace if necessary depending on filter type B Ceramic thermal accumulator Xenion EFP reversible fan double guiding vane wall sleeve Clean C Accessories Check clean or replace if necessary ...

Страница 54: ... GERMANY TELEPHONE 49 0 36427 211 0 FAX 49 0 36427 211 113 E MAIL INFO INVENTER DE WEBSITE WWW INVENTER DE CEO ANNETT WETTIG VAT ID NUMBER DE 815494982 JENA DISTRICT COURT HRB 510380 ALL RIGHTS RESERVED PICTURE CREDITS INVENTER GMBH 2020 SUBJECT TO MODIFICATIONS ALL INFORMATION IS SUPPLIED WITHOUT GUARANTEE NO LIABILITY IS ACCEPTED FOR PRINTING ERRORS COMPANY INFORMATION ...

Страница 55: ... inventer de Version 09 2020 Subject to modifications Article number 5001 0031 inVENTer GmbH 2020 inVENTer GmbH Ortsstraße 4a 07751 Löberschütz Germany 49 0 36427 211 0 49 0 36427 211 113 info inventer de ...