87
CLEANING AND CARE
inVENTer Connect controller platform | Operating instructions
The following installation steps are described using the flush-mounted version of the inner cover,
but apply equally to the surface-mounted version.
Cleaning/replacing the dust filter | System cleaning
Requirements:
•
The LED on the controller is flashing RED
• The error code
F 06 (filter change required) or
F07 (service of the ventilation devices necessary)
is displayed.
•
The app reports in a message that the filter needs
to be changed and/or the ventilation system needs
to be serviced.
NOTICE:
To clean and check the filter, first remove the closing flap on the inner cover.
To do this, the entire ventilation system must be switched off at the controller or paused so that
the closing flap's locking arm moves to the right.
Never swivel the locking arm by hand.
►
Pause the ventilation device or switch it off (
3.6
[Controller] and/or
4.2 | 4.8 [App]).
The swivel arm moves to the right.
►
Pull the closing flap forward, away from the
electronics cover ( ).
►
Press the spring clip at the top slightly downwards
( ) so that it slides out of the opening when the
electronics cover is pulled forwards.
►
Lift the lower lugs out of the guide (
3
).
►
Remove the closing flap from the front.
You have removed closing flap on the inner
cover.
1
2
2
1
3