After Use

8 After Use

8.1 Recycling Information

This product has been supplied from an environmentally
aware manufacturer who complies with the Waste Electrical
and Electronic Equipment (WEEE) Directive 2012/19/EU. This
product may contain substances that could be harmful to
the environment if disposed of in places (landfills) that are
not appropriate according to legislation.

Follow local governing ordinances and recycling plans
regarding disposal of the concentrator or components
normally used in operation. The concentrator does not
generate waste or residue in operation.

DO NOT dispose of the concentrator in the normal
waste stream.

Any accessories not part of the concentrator MUST
be handled in accordance with the individual product
marking for disposal.

Invacare is continuously working towards ensuring that the
company’s impact on the environment, locally and globally,
is reduced to a minimum. We comply with the current
environmental legislation (e.g. WEEE and RoHS directives).
We only use REACH compliant materials and components.

8.2 Wear and Tear

Invacare reserves the right to ask for any item back that
has an alleged defect in workmanship. See Warranty that
shipped with the product for specific warranty information.

Refer to this user manual for proper preventive maintenance
schedule and use of the product.

This is just a general guideline and does not include items
damaged due to abuse and misuse.

Normal wear and tear items and components for this
product are listed below.

All types of filters

All types of tubing

Sieve is a porous filtering material and is considered
a wear item. Some factors that could affect
sieve material life include humidity, temperature,
particulates, air contaminates, air intake, vibration
and other environmental conditions.

1195054-B

33

Содержание Platinum IRC9LXO2AWQ

Страница 1: ...inum Oxygen Concentrator IRC9LXO2AWQ en HomeFill System Compatible User Manual This manual MUST be given to the user of the product BEFORE using this product this manual MUST be read and saved for fut...

Страница 2: ...ed by and All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted Platinum is a registered trademark in the U S A Europe and Australia Making Life s...

Страница 3: ...ning the Nasal Cannula 22 6 3 3 Turning the Concentrator On 24 6 3 4 Flowrate 25 6 3 5 SensO2 Oxygen Purity Indicator 26 6 3 6 Initial Startup of the Concentrator 26 6 3 7 Explanation of Oxygen Purity...

Страница 4: ...ates a potentially hazardous situation which if not avoided may result in property damage or minor injury or both Gives useful tips recommendations and information for efficient trouble free use Symbo...

Страница 5: ...ical Hazard Manufacturer Call supplier This product complies with Directive 93 42 EEC concerning medical devices The launch date of this product is stated in the CE declaration of conformity EC Repres...

Страница 6: ...roduct if the patient is capable of spontaneous breath able to inhale and exhale without the use of a machine DO NOT use in parallel or series with other oxygen concentrators or oxygen therapy devices...

Страница 7: ...evice is not intended to sustain or support life The oxygen concentration level of the output gas ranges from 87 to 95 6 The oxygen is delivered to the patient through the use of a nasal cannula The I...

Страница 8: ...ly B Specification label is located on the back of the concentrator at the base C Double insulation label is located on the back of the concentrator at the base D IRC9LXO2AWQ 2 2 General Guidelines In...

Страница 9: ...ire Textiles oil or petroleum substances grease greasy substances and other combustibles are easily ignited and burn with great intensity in oxygen enriched air and when in contact with oxygen under p...

Страница 10: ...ricity created by any type of friction Keep the oxygen tubing cord and concentrator out from under such items as blankets bed coverings chair cushions clothing and away from heated or hot surfaces inc...

Страница 11: ...chemicals from airway contamination DO NOT use the concentrator in the presence of pollutants smoke fumes flammable anesthetics cleaning agents or chemical vapors WARNING Risk of Injury or Death To pr...

Страница 12: ...adversely affect the flowrate and the percentage of oxygen and consequently the quality of therapy WARNING Risk of Injury or Damage Invacare oxygen concentrators are specifically designed to minimize...

Страница 13: ...c interference in a typical home healthcare environment Use of this equipment in an environment with higher levels of interference could affect the accuracy of the oxygen concentration being delivered...

Страница 14: ...es Not Shown HomeFill Home Oxygen Compressor IOH200AW The HomeFill outlet fitting I is to be used only for filling oxygen cylinders with the HomeFill Home Oxygen Compressor The outlet fitting does not...

Страница 15: ...Components 3 2 Pneumatic Diagram Fig 3 1 Concentrator without Humidifier Fig 3 2 Concentrator with Humidifier 1195054 B 15...

Страница 16: ...al cannula mask tubing humidifier etc used to deliver oxygen to the patient need to include a means to reduce the propagation of fire in the accessories for the safety of the patient and others If a c...

Страница 17: ...ygen concentrator is to be used IMMEDIATELY leave concentrator in its packaging for storage until use is required 5 2 Inspection 1 Inspect examine exterior of the concentrator for nicks dents cracks s...

Страница 18: ...Injury To avoid injury during therapy The oxygen concentrator MUST be placed on a level surface for use DO NOT relocate the oxygen concentrator while in use WARNING Risk of Injury or Damage To avoid...

Страница 19: ...r if so prescribed 6 3 1 Setting Up the Humidifier If Prescribed WARNING Risk of Injury or Damage To avoid burns from steam or hot water inhalation of water and or water damage to the concentrator DO...

Страница 20: ...l to room temperature prior to use CAUTION Risk of Damage Confirm the humidifier cap is not cross threaded on the humidifier bottle 3 Insert a flathead screwdriver in the plate groove C on the top edg...

Страница 21: ...humidifier bottle adapter tube H to the oxygen outlet connector I on the concentrator When using tubing connections longer than 2 1 m 7 ft in length position the humidifier as close to the patient as...

Страница 22: ...asal cannula and tubing Close supervision is necessary when the nasal cannula is used by impaired individuals or near children and or impaired individuals WARNING Risk of Injury or Death To reduce the...

Страница 23: ...acturer 3 Perform one of the following For use with a humidifier bottle Attach the patient s nasal cannula supply tube B to the humidifier bottle outlet M For use without a humidifier bottle Attach th...

Страница 24: ...ncentrator and accessories place the end of the nasal cannula under the surface of a half full cup of water only when the oxygen is flowing and look for bubbles indicating proper operation Wipe any ex...

Страница 25: ...To properly read the flowmeter B locate the prescribed flowrate line on the flowmeter Next turn the flow knob until the ball C rises to the line Now center the ball on the L min line prescribed 2 If t...

Страница 26: ...will come on indicating the unit is operating and is in the initial warm up period When the green light comes on the unit is in normal operating mode SYSTEM OK O2 greater than 85 Once in normal operat...

Страница 27: ...r C SYSTEM FAILURE O2 below 73 RED light Solid Continuous Audible Alarm Sieve GARD Compressor Shutdown SYSTEM FAILURE Total unit shutdown Immediately switch to backup oxygen supply and call supplier D...

Страница 28: ...l components of the concentrator To avoid damage or injury from electrical shock Turn Off the concentrator and unplug the power cord before cleaning DO NOT allow any cleaning agent to drip inside the...

Страница 29: ...terior case 2 Allow the concentrator to air dry or use a dry towel before operating the concentrator 7 3 Cleaning the Cabinet Filter CAUTION Risk of Damage To avoid damage to the internal components o...

Страница 30: ...the filter include but are not limited to high dust air pollutants etc 2 Clean the cabinet filter with a vacuum cleaner or wash with a mild liquid dish detergent such as Dawn and water Rinse thorough...

Страница 31: ...personnel should perform cleaning and disinfection of the oxygen concentrator and accessories between patients Follow these instructions to eliminate possible pathogen exchange between patients due to...

Страница 32: ...HEDULE OR BETWEEN PATIENTS Every 3 years of continuous use Equivalent to 26 280 hours Check Oxygen Concentration green indicator light Clean Replace Cabinet Filter s Refer to Cleaning the Cabinet Filt...

Страница 33: ...orking towards ensuring that the company s impact on the environment locally and globally is reduced to a minimum We comply with the current environmental legislation e g WEEE and RoHS directives We o...

Страница 34: ...rvice supplier 4 Turn power switch off and allow unit to cool Do one or both of the following a Remove and clean cabinet filters b Move oxygen concentrator at least 30 5 cm 12 in away from walls drape...

Страница 35: ...power back On 2 Reset flowmeter to prescribed flowrate Alarm System Failure YELLOW light Illuminated Short beeps long pause Beep Beep 1 Low oxygen purity 2 Kinked or blocked tubing cannula or humidifi...

Страница 36: ...ut Concentration Levels 92 minimum at 1 to 2 L min 93 minimum at 3 to 7 L min 91 minimum at 8 L min 87 minimum at 9 L min Concentration levels achieved after initial warm up period approximately 30 mi...

Страница 37: ...tdown Low Pressure Alarm with compressor shutdown Battery Free Power Loss Alarm SensO2 Oxygen System Possible Obstruction Alert Width 46 7 cm 1 cm 18 3 8 in 3 8 in Height 67 0 cm 1 cm 26 3 8 in 3 8 in...

Страница 38: ...t air flow Avoid deep pile carpets and heaters radiators or hot air registers Floor location only No confined spaces Example No closets Environment Smoke and soot free Tubing Recommended use up to 15...

Страница 39: ...ons flicker emissions IEC 61000 3 3 Complies The Device is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power supply...

Страница 40: ...vironment If the user of the Device requires continued operation during power mains interruptions it is recommended that the Device be powered from an un interruptible power supply or a battery UT is...

Страница 41: ...ts W according to the transmitter manufacturer and d is the recommended separation distance in metres m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a sho...

Страница 42: ...RF communications equipment and the Device The Device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the Device can...

Страница 43: ...ency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer At 80 MHz and 800 MHz the separation distance for the higher...

Страница 44: ...Poirier SAS Route de St Roch F 37230 Fondettes Tel 33 0 2 47 62 64 66 Fax 33 0 2 47 42 12 24 contactfr invacare com www invacare fr Ireland Invacare Ireland Ltd Unit 5 Seatown Business Campus Seatown...

Страница 45: ...z Suisse Svizzera Invacare AG Benkenstrasse 260 CH 4108 Witterswil Tel 41 0 61 487 70 80 Fax 41 0 61 487 70 81 switzerland invacare com www invacare ch United Kingdom Invacare Limited Pencoed Technolo...

Страница 46: ...Notes...

Страница 47: ...Notes...

Страница 48: ...3 Tel 800 832 4707 www invacare com Manufacturer Invacare Corporation 2101 E Lake Mary Blvd Sanford FL 32773 United States Tel 407 321 5630 EU Representative Invacare Deutschland GmbH Kleiststra e 49...

Отзывы: