Appendix B – Inband Management Connection Troubleshooting
90
Appendix B – Inband Management Connection
Troubleshooting
,
Continued
Fail-safe
procedure 1
(arp-s
commands)
,
continued
Step
Action
3
Enter the following static ARP cache entry and press ENTER:
Static ARP entry is not required when management
VLAN is assigned as default VLAN on the connection
port.
arp-s 10.255.255.254 00-05-59-64-06-33
4
Verify that you can ping the node, by entering the fail-safe IP address
and press ENTER:
ping 10.255.255.254
Echo replies should appear:
Node replies to ARP requests of fail-safe IP address
when the Ethernet link is up.
5
Access WiBAS via
Node Manager
by entering the fail-safe IP
address (10.255.255.254).
6
Perform a
Restore Factory Default Configuration
action to clear
any previous configuration on node:
i.
From the Menu, select
Maintenance & Troubleshoot
>
Maintenance
.
ii.
In the
Configuration Operations
>
Restore Default
Configuration
group box, select
Factory
and click
Restore
.
iii.
In the confirmation message that appears, click
Yes
. The
WiBAS returns to factory default configuration and then
reboots.
7
Login again to WiBAS ,
by entering the default inband IP address
(10.10.10.100/24).
End of procedure.
Continued on next page