![Intracom WiBAS Connect Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/intracom/wibas-connect/wibas-connect_commissioning-manual_2081786065.webp)
WiBAS OSDR-Hub & Terminal Station / WiBAS-Connect Terminal Station
Start Up & Commissioning Manual - Edition 5.1
65
WiBAS-Connect TS
,
Continued
Procedure for WiBAS-Connect TS with Parabolic Low Profile Antenna
,
continued
Step
Action
5a
Perform fine alignment, as follows:
•
Use the spanner key to loosen the azimuth adjustment bolts
(A)
. Perform azimuth
adjustment by holding tool’s handles firmly and slightly move the antenna/radio
combo (within the
±
10
o
range around the azimuth axis)
until the voltage readout
reaches a desired level.
(A) = Azimuth bolts x 2 (up and down)
The RSSI voltage
(actually the voltmeter value)
provides a direct
relationship with RSL.
For
WiBAS-OSDR
see
WiBAS-OSDR terminal station RSSI measurement
For
WiBAS-Connect
see
WiBAS-Connect terminal station RSSI
measurement calculation formula
on page
6a
Use the adjustable torque wrench for pre-tightening.
The final tightening torque
will be applied after alignment process completion.
Continued on next page