6. Equipment Commissioning
80
WiBAS-Connect TS (Auto-Polarization Edition)
,
Continued
Procedure for WiBAS-Connect Auto-Polarization TS with Parabolic Low Profile Antenna,
continued
Step
Action
10
If the values are the expected ones, then secure the antenna to the final position.
Use the adjustable U-wrench to apply the final tightening torque to the bolts,
as follows:
•
M5 bolts max tightening torque
5.5 Nm
.
•
M8 bolts max tightening torque
15 Nm
.
•
U-Bolt fully tightening.
Do not over tighten
. Overtightening will cause deformation
of the support clamp.
Do not over tighten.
Be very careful when tightening the adjustment bolts not to move the
antenna.
After alignment completion DO NOT leave radio unit RSSI receptacle without
cover. Covering receptacles protect against humidity penetration.
End of procedure