![Intracom WiBAS Connect Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/intracom/wibas-connect/wibas-connect_commissioning-manual_2081786059.webp)
WiBAS OSDR-Hub & Terminal Station / WiBAS-Connect Terminal Station
Start Up & Commissioning Manual - Edition 5.1
59
WiBAS-Connect TS
,
Continued
Procedure for
WiBAS-
Connect TS
with Panel
Antenna
To perform WiBAS-Connect TS panel antenna alignment, please follow the
steps below:
Step Action
1
Perform coarse alignment,
as follows:
Use the respective spanner key to rotate the assembly on the pole so that the
antenna is “visually” aligned with the target base station sector.
Use compass and binoculars for alignment.
Use the RF planning values for aligning the assembly to the target base
station sector.
Use the adjustable U-Wrench to apply the
final tightening torque
(M8 u-
bolts nuts max tightening torque
15 Nm
).
U-Bolt fully tightening.
Do not over tighten
. Overtightening will cause
deformation of the support clamp.
2
Power on the terminal station.
Connect the RSSI cable as described to
RSSI cable connection procedure
on page
42
.