![Intracom WiBAS Connect Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/intracom/wibas-connect/wibas-connect_commissioning-manual_2081786058.webp)
6. Equipment Commissioning
58
WiBAS-Connect TS
,
Continued
Procedure for WiBAS-Connect TS with Parabolic Integrated Antenna
,
continued
Step
Action
4
Log in to the aligned terminal station as described to
Go to
Summary
and check the RSSI & SNR value, as shown below:
Press the refresh button to get the latest value.
5
If the values are the expected ones, then secure the antenna to the final position.
Use the adjustable U-wrench to apply the final tightening torque to the bolts
(follow the tightening torque values provided by the Installation Instructions of the
corresponding antenna).
Do not over tighten.
Be very careful when tightening the adjustment bolts not to move the
antenna.
After alignment completion DO NOT leave radio unit RSSI receptacle without
cover. Covering receptacles protect against humidity penetration.
End of procedure.
Continued on next page